My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002 - 2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2002 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:27:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2008
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\18754\PR0507164\COMPLIANCE INFO 2002 - 2008 .PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2008
QuestysRecordDate
1/17/2017 5:26:41 PM
QuestysRecordID
3312375
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S W RC B, January 2002 FrNAL DRAFT <br />8. FILL RISER ('.ONTATNINFNT CTTK P 'rae�Tr <br />Page 6 of 7 <br />Facility is Not Equipped With Fill Riser Containment Sump(s) ❑ �i <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />j Test Method Developed By. ❑ Sump Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />-- <br />Ies; Method Used: ❑ Pressure ❑ Vacuu : ❑ H,:drosratic — — —� <br />❑ Other (Speci <br />Test Equipment Used: = <br />Fill Sump TM Fill Sump n <br />Equipment Resolution: <br />Fill Sump = <br />Fill Sump 9 <br />Sump Diameter: <br />Sump Depth: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condiiiou ui'sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test StartTime: <br />Initial Reading (R;): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -Rt): <br />Pass/Fail Threshold or Criteria: <br />Test Result <br />OPass EDFai] <br />Pass Fail <br />Is there a sensor in the sump? <br />Yes No <br />❑ <br />Yes No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑Yes ❑No ❑NA <br />❑❑Yes <br />=E)Faj'IPass <br />[]No [:INA <br />u W`as sensor removed fo_r testing? <br />Yes No NA <br />_Yes No NA <br />Yes No INA <br />YeONoTTNA <br />was sensor property replaced and❑Yes <br />verified functional after testing? <br />❑Yes ❑No ❑NA I <br />❑Yes ❑No ❑NAI <br />❑Yes ❑No ❑NA I <br />[I No ❑NA <br />Comments — (Include information on repairs made prior to testing and recommended follow-up fir jailed tests.) <br />
The URL can be used to link to this page
Your browser does not support the video tag.