COMPLIANCE INFO_2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
8203
>
2300 - Underground Storage Tank Program
>
PR0231595
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/6/2018 9:32:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0231595
PE
2361
FACILITY_ID
FA0003591
FACILITY_NAME
JOHN M RISHWAIN
STREET_NUMBER
8203
Direction
E
STREET_NAME
STATE ROUTE 26
City
STOCKTON
Zip
95215-9536
APN
10114021
CURRENT_STATUS
02
SITE_LOCATION
8203 E HWY 26
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 26\8203\PR0231595\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />E3 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 408-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Jims' 24 HR Gas'N Go <br />Name: <br />Facility <br />Address: 8203 East Highway 26, Stockton <br />Inspection <br />Jun 26, 2014 <br />Date: <br />VIOLATIONS <br /># <br />I C1 <br />I C2 <br />M <br />I Code Section <br />HSC = CA Health and Safe Code: CFR = Code Federal Regulations <br />Cl =Class 1 violation; C2 =Class 2 violation; M =Minor violation <br />M <br />on Site Records (continued) - '.' , <br />204 X CCR 2715(c) Designated operator monthly inspection: (1) alarms not documented; (2-4) spill containers, UDCs, and sumps <br />if necessary)not inspected; 5 required test dates not checked or noted; 6 employee trainingnot verified <br />205 X CCR 2715(e) Designated operator monthly inspection <br />reports not maintained on site for at least 12 months <br />206 X CCR 2715(f) Designated operator employee training: t 1 not per (2) not current for at least one employee on site; <br />3 to not kept <br />207 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />-" observations - -- - <br />301 X HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 X HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(mi) <br />303 X CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br />304 X CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST <br />(Mt) <br />305 X CCR 2636(()(1) Failed to maintain a wntinuous monitoring system for underground piping & UDCs that activates an (M1) <br />audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 <br />CCR 2631(a) Primary containment isnot product tight <br />307 HSC 25291(a)(2) Secondary containment for UST system is not tight <br />308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />309 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) <br />(M2) <br />310 HSC 25291(e) Water in 2- containment not removed, analyzed & proper) disposed of <br />311 X CCR 2636(f)(2) Line leak detectors) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (M1) <br />312 CCR 2635(b) No spill container or overi"I prevention system installed <br />(M2) <br />313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (M2) <br />the s ill container em <br />—T14 <br />X CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements <br />(M2) <br />315 X HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br />316 CCR 2631.1(a) UST system is not compatible with the substance stored <br />317 X HSC 25298(a) Illegally abandoned UST system <br />AB 1702 (2003-2004) HSC 25290.2 (installed between 07/01/03 and 06/30/04) <br />VPH Systems HSC 25290.1 finstalled on or after 07/01/04 <br />401 <br />CCR 2631.1 <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />results of the compatibility and permeability testing requirements listed in <br />subsections CCR 2631(b) and (d) <br />for a UST system installed after July 1, 2004 were not submitted <br />402 <br />HSC 25290.1(c)(1) <br />WNW— <br />Primary containment not liquid or vapor tight <br />403 <br />HSC 25290.2 c)(2 <br />Secondary containment not liquid or vapor tight <br />404 <br />HSC 25290.1 (c)(3) <br />HSC 25290.2(c)(3)Secondary <br />Seconds containment not constructed to prevent water intrusion <br />405 <br />HSC 25290.1(d) <br />HSC 25290.2 d <br />Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />li <br />uid or vapor from the rima containment into the secunda containment <br />406 <br />HSC 25290.1(e) <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST system not maintained <br />407 <br />HSC 25290.10) <br />UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />HSC 25290.2 <br />ressure test approved by SWRCB; 3 test method deemed equivalent to 1 or 2 by the SWRCB <br />Emergency Generator Systems <br />501 CCR 2636(f)(6) Emergency generator monitoring system not checked daily or log not kept if no leak detector (Mt) <br />502 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept <br />(Mill <br />USTs in a Vault <br />601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br />603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 HSC 25283.5(a)(5) UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />.Non -Pressurized Piping <br />101 CCR 2643(d) Daily monitoring of suction piping (pre -January 1, 1984) not performed (M1) <br />Inspector. Received Bg TiGe: <br />Jeffrey Wong (209) 468-0335 <br />"""°-" 1Cv04„22'° Paget UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.