My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THURMAN
>
850
>
2300 - Underground Storage Tank Program
>
PR0536287
>
COMPLIANCE INFO PRE 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2025 4:38:33 PM
Creation date
11/6/2018 10:10:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2016
RECORD_ID
PR0536287
PE
2332
FACILITY_ID
FA0018160
FACILITY_NAME
ARMOR STRUXX LLC
STREET_NUMBER
850
STREET_NAME
THURMAN
STREET_TYPE
St
City
LODI
Zip
95240
APN
04931018
CURRENT_STATUS
02
SITE_LOCATION
850 Thurman St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\THURMAN\850\PR0536287\COMPLIANCE INFO PRE 2016.PDF
QuestysFileName
COMPLIANCE INFO PRE 2016
QuestysRecordDate
7/26/2016 6:50:44 PM
QuestysRecordID
3152716
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.siclov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> ArmorStruxx 500 S. Beckman Rd. Lodi, CA 95240 May 17, 2011 <br /> VIOLATIONS R <br /> # Code Section V <br /> HSC=CA Health 8 SafetyCode;CCR=CA Code of R ulations;V=Violation- RV=Re at Violation V <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(2-4)spill containers, <br /> 23c CCR 2715(c),(e) UDCs,and sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted;(c)(6) <br /> employee training not verified; (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1)not performed;(2)not current for at least one employee <br /> on site; 3 log not kept <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or certification;(f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment component that was certified, repaired,or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed IM71 <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line ti htness test not performed if positive shutdown or fail safe not present (MI) <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (11112) <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity pipingnot p2rfbaned re-Janus 1 1984 fat <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984 (MI) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit toreair UST system not obtained <br /> 33 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 34 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 35 HSC 25298(c) Permit to dose UST system not obtained <br /> 36 HSC 25299(f)(2)_ Tam ring with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5 b)(2) Unburied fuel piping at marinas not visual) inspected at least dailyor I not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 1 CCR 2636(f)(6) Emerqenc enerator monitorin system not checked dailyor I not kept if no leak detector rat <br /> 41 HSC 25281.5(b)(3) Unburied fuel <br /> ug <br /> Ing not visually inspected at least monthly or 129 not kept IMt) <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 06/30/04) <br /> VPH Systems HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements: (a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631 b and d for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) primary containment not liquid or vapor tight <br /> HSC 25290.2 c 1 <br /> 44 HSC 25290.1(c)(2 2) <br /> HSC 25290.2(c2) <br /> 5290.2 c Secondary containment not liquid or vapor tight <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or (1x1) <br /> HSC 25290.2(d) the entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial IMlI <br /> space of the UST s stem not maintained <br /> HSC 25290.1 Q) UST system not tested by one of the following methods prior to use: (1)Enhanced leak detection;(2) <br /> 48 HSC 25290.2(1) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 1 Other. See attached"Continuation-Offidal Inspection Report"for violation(s)not listed above. <br /> EHD inspector. Phone: UIC <br /> (209) 468-3453 Septic system: <br /> F1 Serves 20 peoplelday <br /> Recei TNe: ❑Receives other than sanitary waste <br /> J / <br /> Other disposal methods' <br /> tlt'ta----- 4r11 11 Dry wells/French Drains <br /> EHD 23-02-002 REV 08113/10 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.