Laserfiche WebLink
SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s'gov.ora/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> ArmorStruxx March 13, 2012 <br /> Facility address: UST#I 1 2 <br /> 500 S. Beckman Rd. Lodi, CA 95240 Product Wdraulicoil rydraulicoi <br /> Facility contact Title: Phone: <br /> Aaron Allen EHS/Facility Mgr. (209) 371-8011 <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> visual monitoring ❑X Pressurized❑Suction❑Grav"ty ❑Mechanical ❑Mt-RDetect❑M2-RPrev❑M3-Both <br /> ❑AudibleNisual <br /> Inspection type: Designated operator. ICC exp.date: <br /> ❑x Routine ❑Monitoring certification ❑Installation E]Other n/a <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> n/a <br /> # Code Section VIOLATIONS R <br /> HSC=CA Health&Safe Code;CCR=CA Code of Regulations;V--Violation; RV=Re at Violation V V <br /> 1 HSC 25284 No permit to operate <br /> Secondary containment: (a)test not performed; (e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Fortes not on file with the EHD(Facility and tank forth <br /> 4 HSC 25292.2 Current financial res onsibili documents not on file with the EHD <br /> 5 1 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current o approved by the EHD <br /> 6 1 CCR 27120) Monitoring Ian,response plan, and/or operating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/ (Mf) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records; (3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed Mt <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST IM11 <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates IMtI <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not ti ht <br /> 16 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(1f)(2) Line leak detectors not installed or failed to detect a 3-gallon r hour leak at 10 si IMtI <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (11112) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill reuirements in this section (1112) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(inrludes conventional suction piping) (111112) <br /> 21 HSC 25291 a Water in 2°Containment not removed, analyzed&property disposed of <br /> Unauthorized release that:(C)did not escape secondary containment and cleaned up within eight (Mt) <br /> 22 CCR 2650 hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> JiV6 <br /> Failed to inform the EHD of a AL change of designated o rotor within 30 clays <br /> Desi nated o rotor did not osseas a current ICC UST S stem O rator certification <br /> Received by: Title: <br /> df <br /> EHD 23-02-002 REV 08/13110 Page 1 UST INSPECTION REPORT <br />