My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TOKAY
>
32
>
2300 - Underground Storage Tank Program
>
PR0231378
>
BILLING 1985-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2024 10:54:07 AM
Creation date
11/6/2018 10:11:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-2002
RECORD_ID
PR0231378
PE
2361
FACILITY_ID
FA0003901
FACILITY_NAME
PACIFIC COAST PRODUCERS (TOKAY)
STREET_NUMBER
32
Direction
E
STREET_NAME
TOKAY
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04703020
CURRENT_STATUS
02
SITE_LOCATION
32 E TOKAY ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TOKAY\32\PR0231378\BILLING 1985-2002.PDF
QuestysFileName
BILLING 1985-2002
QuestysRecordDate
8/17/2017 10:29:17 PM
QuestysRecordID
2595268
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 � � • �aV•cpy <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD ?a,� <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> 1 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ i NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION O 7 PERMANENTLY CLOSED G <br /> ONE REM El INTERIM PERMIT FD AMENDED PERMIT 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> �o S-rX62L--7-, Z-016-=DBA OR FACILITY NAME WHERE TANK IS INSTALLED: G - <br /> - / '.K�1 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> B. MANUFACTURED BY: <br /> A OWNER'S TANK I.D.# <br /> C. DATE INSTALLED(MO/DAY/YEAR) <br /> D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> to REGUUR UNLEADED ❑ 3 DIESEL ❑ 8 AVIATION GAS <br /> A 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C ib PREMIUM UNLEADED ❑ 6 GASAHOL ❑ 7 METHANOL <br /> �2 PETROLEUM ❑ 80 EMPTY � PRODUCT iG MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELO" <br /> C.A.S.#: <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED. <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> 1 DOUBLE WALL E::] 3 SINGLE WALL WITH EXTERIOR LINEfl ❑ 5 INTERNAL BLADDER SYSTEM E] 95 UNKNOWN <br /> A. TYPE OF ❑ 99 OTHER <br /> SYSTEM 2 SINGLE WALL 4 SINGLE WALL IN A VAULT <br /> 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK <br /> MATERIAL 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBL <br /> (Primary Tank) 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ <br /> LINING OR ❑ 5 GLASS LINING ❑ 8 UNLINED 95 UNKNOWN 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 1001% METHANOL? VES_ NO— <br /> D.EXTERIOR El ' POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION ❑ 95 UNKNOWN ❑ 99 OTHER <br /> PROTECTION 5 CATHODIC PROTECTION ❑ gt NONE <br /> SPILL <br /> CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> E.SPILL AND OVERFILL,etc. DROP7UBE YES___ NO STRIKER PLATE VES_ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> 1 MECR?NICAL ONE LEAX 2 UNE TIGHTNESS ❑3 CGN9N000S arrEASMW ❑4 RE LWK�CO <br /> UNE [:]5=PUMP ❑ 99 OTHER <br /> D. LEAK DETECTION ❑ D croft ❑ MTRIG uoreroRlxG <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 MANUAL INVENTORY ❑ 3 MONO ORING 4 GAUGING AUTOMATIC TANK ❑ 6 GROUND MONITORING TESTING <br /> ❑ e ANNUALTESTINGTANK <br /> RECONCILIATION <br /> O 7 MOESTING <br /> NTORWG INTERSTITIAL ❑ 8 SIR 9 TANKLY MANUAL ❑10 MONTHLY TANK ❑ 95 UNKNOWN 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH VES ❑ NO E]1.ESTIMATED DATE LAST USED(MO/DAVlYR) SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> DATE <br /> TANK OWNER'S NAME <br /> (PRINTED 8 SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# r�_7,�7— <br /> STATE I.D.# Ur-r�'F J� aIIJ�LI I JI <br /> PERMIT NUMBER PERMIT APPROVED SYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLI ION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. F MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING TH RGROUND STORAGE TANK REGULATIONS <br /> FORMS (6-95) <br />