My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1986-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TOSTE
>
2450
>
2300 - Underground Storage Tank Program
>
PR0501204
>
BILLING 1986-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2024 11:14:17 AM
Creation date
11/6/2018 10:21:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1986-2002
RECORD_ID
PR0501204
PE
2381
FACILITY_ID
FA0010191
FACILITY_NAME
TRACY-PONTIAC-CADILLAC-GMC TRUCK
STREET_NUMBER
2450
STREET_NAME
TOSTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
238020-06
CURRENT_STATUS
02
SITE_LOCATION
2450 TOSTE RD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TOSTE\2450\PR0501204\BILLING 1986-2002.PDF
QuestysFileName
BILLING 1986-2002
QuestysRecordDate
8/17/2017 9:41:44 PM
QuestysRecordID
3588538
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI WATER RESOURCES CONTRO,OARD <br /> FORM 'B': UNDEROUND STORAGE TANK PRO AM y <br /> TANK PERMIT APPLICATION INFORMATION ° <br /> TANK �GIbM0LkfI A 0PANATE FORM WITH THE FOLLOWING!pKORMATION FOR EACH TANK. <br /> MARK ONLY ❑ I NEW PERMIT F-13 RENEWAL PERMIT CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOS / <br /> ONE ITEM ❑2 INTERIM PERMIT F-14 AMENDED PERMIT ❑1 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED r `] <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED; ZI S !� �Cli7 E /�-�� FARM TANK-YES❑t NO O <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-80 SPECIFY <br /> A. OWNERS TANK IDN B. MANUFACTURED BY: YV1 O 7/1'IV <br /> C.YEAR INSTA D G�� D. TANK CAPACITY IN GALLONS t 000 0 <br /> 11. TANK RtiNTENTS IF(A•1),18 MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> 3 DIESEL <br /> A. 1 MOTOR VEHICLE FUEL F-12 PETROLEUM C. I UNLEADED ❑ 2 LEADED <br /> B. ❑ <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑ 4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑BO EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.It: <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.N <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> w A TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ I STEEUIRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLADW/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK �❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUSBERLINED ❑2 AUKYD LINING ❑ 3 EPDXYLINING ❑4 PHENOLIC LINING <br /> C. INTERIOR ❑5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> LINING <br /> ❑ IS LIMNG MATERIAL COMPATIBLE WITH IODI6 METHANOL? ❑YES ❑NO ❑99 OTHER <br /> 0.CORROSION ❑ I POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 9/ NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK 11 8 2 INVENTORY RECONCILIATION 0 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 8 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3, WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 6 SIGNATURE) DATE <br /> I <br /> LOCAL AGENCY USE ONLY _. <br /> COUNTY N JURISDICTION k AGENCY M FACILITY ID R TANK ID N <br /> CURRENT LOCAL AGEfNNCY FACILITY)o N APPROVED BY NAME PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVALOATE PERMIT EXPIRATION DATE <br /> C _L <br /> CHECK F PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT A BY:tl-�1417 <br /> FORMB(6-29-88) THIS FORM MUST BE ACC;MPAN11reyAFACILRY/BRE APPLICATION, FORM 'A,UNLESS ACURRENT FORMA' HASBEENFILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.