INSTALL AST TO UST INSTALL PLAN 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3940
>
2300 - Underground Storage Tank Program
>
PR0507837
>
INSTALL AST TO UST INSTALL PLAN 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:01 PM
Creation date
11/6/2018 10:48:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
AST TO UST INSTALL PLAN 2011
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\3940\PR0507837\INSTALL\AST TO UST INSTALL PLAN 2011.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FE PEMO High Capacity Pumps <br /> High Capacity Submersible Turbine Pump Specifications <br /> _ _High — Liquid Compatibility <br /> CapacityPump Model _ •Max.liquid viscosity:70 SSU at <br /> SubmTurbine <br /> Designation System 60"F(15"C). <br /> •Standard models are UL and cUL listed for <br /> A typical turbine model designation fuel mixtures containing up to I S%ethanol <br /> has up al five nem oriel de to define or methanol,and 20%MTBE,20%ETBE or <br /> 17%TAME with gasoline. <br /> the pump being supplied as follows: <br /> B •STPAG models are compatible with fuel <br /> STP XXXXX Y- A- B 1 mixtures containing up to 100%ethanol or <br /> - --- -' methanol,and 20%MTBE,20%ETBE or <br /> STIR Basic Model Designation -`m�= -= =P� <br /> 17%TAME with gasoline. <br /> XXXXX = Factory •HCP models can also be used with diesel <br /> Installed Options fuels,fuel oils,kerosene,Avgas and jet fuels <br /> HCP model designations may include A in a non-gelled pourable state. <br /> one or more of the following •All wetted elastomers are made of a high <br /> characters in alphabetical order: grade,fluorocarbon Vitonv compound. <br /> AG=Alcohol-gasoline compatible <br /> (100%ethanol or methanol capable) Standard Features <br /> Note:Standard models 0%to 15% •Pressure relief valve:cartridge design <br /> ethanol or methanol capable available in two pressure relief settings, <br /> F=Floating suction adapter external to check valve.Standard model <br /> (3"NPT male adapter) relieves at 40 psi and resets above 35 psi. <br /> 'R=Model R check valve •Syphon:external venturi-type syphon <br /> (24 psi relief/22 psi reset for PLLD) primer supplied as submersible accessory. <br /> 'Note:If not otherwise specified,all For full diagram see page 38. •Air eliminator:every submersible <br /> HCP models supplied with includes tank return path to provide active <br /> standard model check valve Power Requirements air elimination. <br /> (40 psi relief/35 psi reset for <br /> MLD and TS-LS300). •High capacity pump models require Approvals <br /> three-phase,60 Hz incoming power. PP <br /> Pump Motor Horsepower/ "High capacity pump models are •Consult factory for applicable approvals. <br /> Electrical Rating available as 208-230 VAC,460 VAC or <br /> 3=3 hp fixed speed,208-230 VAC 575 VAC versions. Quality Certification <br /> 5=5 hp fixed speed,208-230 VAC •Hi h capacity pump models are available in .Franklin Fueling Systems is an ISO 9001 <br /> 5H=5 hp fixed speed,460 VAC hp d 5 hp versions. Certified Manufacturer. <br /> SG=5 hp fixed speed,575 VAC <br /> _SC <br /> three-phase smart controllers -Vttone is a registered trademark of DuPont <br /> and STP-CB3/5 three-phase control boxes Dow Elastomers. <br /> A= Model Length are available for high capacity pump control. <br /> Model length is expressed as three <br /> numeric characters that indicate the Pump Motor <br /> length of the HCP from the turbine .Fixed speed,3450 rpm,multi-stage �� D$ LISTED <br /> manifold bottom to the pump motor centrifugal type pump motor with built-in, <br /> inlet in inches,available from 60"to automatic,thermal overload protection. <br /> 200"(additional charge for models <br /> 132"and longer). •High capacity pump 60 Hz models are <br /> available as two-stage versions only. <br /> B=Riser Pipe Length <br /> Riser pipe length is expressed as <br /> two numeric characters that indicate <br /> the total length of the riser in inches. <br /> Riser pipes are available from 6"to <br /> 60"in three inch increments <br /> (additional charge and lead time for <br /> risers 33"or longer). <br /> ;e <br />
The URL can be used to link to this page
Your browser does not support the video tag.