My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2017 INSTALL PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10715
>
2300 - Underground Storage Tank Program
>
PR0541281
>
INSTALL 2017 INSTALL PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 4:35:43 PM
Creation date
11/6/2018 10:58:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2017 INSTALL PLANS
RECORD_ID
PR0541281
PE
2361
FACILITY_ID
FA0023650
FACILITY_NAME
Trinity Parkway AMPM ARCO #83819
STREET_NUMBER
10715
STREET_NAME
TRINITY
STREET_TYPE
Pkwy
City
Stockton
Zip
95219
APN
6602002
CURRENT_STATUS
01
SITE_LOCATION
10715 Trinity Pkwy
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\T\TRINITY\10715\PR0541281\2017 INSTALL PLANS.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CUENT: <br /> - � <br /> HYDROSTATIC TEST LEAD CONNECTED TO GROUND ROD by <br /> STANK #2B\ RESERVOIR (NOT LUG OR WIRING) <br /> #4 STRANDED WIRE TOs <br /> 1/2"0 CADWELD GROUND 7 <br /> ROD CONNECTION 10 OHMS MAX <br /> HYDROSTATIC <br /> RESERVOIRo ( ( 1 #4 STRANDED WIRE TO #4 STRANDED #4 STRANDED 2 <br /> 1/2"0 CADWELD GROUND 3 2 BARE COPPER BARE COPPER <br /> 0 o I ROD CONNECTION GROUND TO GROUND <br /> O GROUND ROD TO OTHER TANKS <br /> I fl - I N <br /> FILL SUMP I 5 8 (TYP.) <br /> a' e <br /> TURBINE SUMP �l o <br /> it 6 (TYP.) <br /> "T" CADWELD #4 <br /> ° BOND GROUND WIRE TO /�\�/\// / \ \�/ // // <br /> STRANDED BARE <br /> FILL SUMP ALL METALLIC RISERS <br /> 1/2" 0 X 10' LONG 1 COPPER WIRE <br /> \ AS REQUIRED (TYP.) COPPER CLAD STEELGROUND ROD DETAIL CONNECTION Ir 4"0 BRASS PIPE <br /> GROUND ROD IN <br /> SEE BONDING DETAIL (TYP.) 6 CLAMPS TYP.) ARCO <br /> GROUND ROD INSTALL OUTSIDE OF - --- i <br /> 1 3 NATIVE SOIJ.�-' <br /> TANK EXCAVATION IN NATIVE SOIL / <br /> 4 I � BP WEST COAST PRODUCTS,LLC <br /> °( I (TYP.) <br /> 2 (TYP.) <br /> G,HgV <br /> FILL SUMP i TERMINAL CONNECTION v <br /> ' #4 STRANDED BARE 5 MQ' <br /> ' o0 COPPER GROUND TO W Z <br /> EQUIPMENT SCHEDULE 1 1 3/4" 0 SOLID ROD <br /> CADWELD "L" CONNECTION `k <br /> NOTE: ANCHORING PLATE i (TYP.) p U <br /> ITEM SEE TANK FUELING SITE PLAN <br /> TURBINE SUMP „ <br /> r 3/4"0 x 12 LONG BRASS g _,...�,. .__._. _ . .. _ __..__ 1S <br /> DESCRIPTION FOR SPECIFIC TANK LAYOUT 4" DIA. BRASS\ (TYP.) T�N� ENGI <br /> 6 + / ROD (TYP.) <br /> NO. TANK #2A TANK # 1 GROUND CLAMP\ <br /> 1/2" 0 X 10' LONG COPPERBONDED GROUND \ \ / \ / / /r <br /> ROD: "ERICO" PART NO. 611300 (UL LISTED) �- — ` \ RISER (TYP.) / 18215 72ND AVENUE SOUTH <br /> OR EQUIVALENT <br /> KENT, WA 98032 <br /> O #4 AWG STRANDED BARE COPPER GROUND B — — — B NOREPENETRATIONS OF THE SUMP WALLS, (425)251-6222 <br /> WIRE. PROVIDE TERMINAL CONNECTORS AT SOLID BRASS ROD ARE TO BE USED AND THE (425)251-8782 FAX <br /> U-BOLT CONNECTIONS INTERIOR SUMP GROUND WIRES ARE TO BE cj <br /> GROUND CLAMP AT FILLCONNECTED VIA TERMINAL CONNECTORS TO THE CIVIL ENGINEERING, LAND PLANNING, <br /> OCADWELD 4 WIRE CABLE TO GROUND ROD TYPICAL FILL SUMP SURVEYING, ENVIRONMENTAL SERVICES <br /> BOLTS. BOLTS SEALED BOTH INSIDE AND NOTE: <br /> CONNECTION "ERICO" PART NO. GTT14A1L, USE <br /> -- --------------------------- ---------------------------------------- -------------- SUMP OUT WITH GLASSS MATT & RESIN. ALL EXTERIOR WIRE PENETRATIONS N0. DATE REVISION DESCRIPTION <br /> WELD METAL #32 REQUIRED TO BE CAD WELDED <br /> 2 #4 STRANDED BARE �� ARE REQ <br /> I s-s-Is PERMIT SUBMITTAL <br /> CADWELD "T" CONNECTION FOR #4 BARE / COPPER GROUND EXTREME CAUTION MUST BE OBSERVED WHILE USING ANY NON-INTRINSICALLY SAFE TO ENSURE EFFECTIVE GROUNDING. <br /> (q 1 STRANDED WIRE CABLES. "ERICO" PART NO. i #4 STRANDED 2 TO GROUND CLAMPS \ ' DEVICE IN CLASSIFIED AREAS. SUMP MUST BE TESTED FOR VOLATILE VAPORS PRIOR ' z 12-14-16 PERMIT RESUBMITTAL <br /> TACILIL, USE #32 WELD METAL. BARE COPPER ON FILL RISERS `I ■ TO USE. ELECTRICAL CONNECT MUST BE MADE WITH JUMPER WIRE SO FINAL ■ <br /> #4 STRANDED BARE 2 GROUND 3 1-31-n PERMIT RESUBMITTAL <br /> r CONNECTION IS AWAY FROM CLASSIFIED AREAS. <br /> 3/4" NPT ADJUSTABLE BRASS GROUNDINGCOPPER GROUND TO OTHER TANKS <br /> I 5 3/4" GROUNDING I a B-Is-n coNSTRucnGN RELEASE <br /> O PIPE CLAMP, LIND EQUIPMENT P/N JR-150-6 I TO GROUND ROD CLAMP W/ TAP <br /> (905) 475-5086 i SCREW (TYP.) <br /> C: TESTING EXPOSED GROUND SYSTEM & BONDING DETAILS i 0 u-�n n REV. FOR CONSTRUCT ON <br /> I <br /> 4" NPT ADJUSTABLE BRASS PIPE CLAMP, LIND 8 3/4"0 x 12" LONG <br /> �- � EQUIPMENT P/N JR-150-30 (905) 475-5086 SOLID BRASS ROD I SCALE: NONE B <br /> "T" CADWELD #4 4 (TYP.) GENERAL SHEET NOTES <br /> STRANDED BARE i Q <br /> OPOMECO/OPW 6110-12WT 12" H-20 RATED i COPPER WIRE <br /> ACCESS COVER I CONNECTION <br /> I (TYP.) Q <br /> I <br /> 3/4"0 x 12" LONG SOLID BRASS ROD NOTES: TESTING: A22 <br /> O ALL STAGE I FILL AND VAPOR RISER ADAPTERS SHALL BE ELECTRICALLY GROUNDED CAUTION: AVOID CONNECTING ANY ELECTRICAL TEST LEAD TO THE FILL OR VAPOR SEAL: <br /> I TO PROMOTE THE RELAXATION OF STATIC CHARGE. RISER IN A MANNER THAT WOULD POTENTIALLY PRODUCE STATIC DISCHARGE OR RpFESS10N <br /> O3/4" DOUBLE WALL ENTRY FITTING. I I SPARKS OF ANY KIND. Q q� <br /> „ #4 STRANDED BARE COPPER 5 3 4" FRP BONDED THE BONDING AND GROUNDING FOR STATIC ELECTRICITY PROTECTION SHALL BE IN O F <br /> BRAVO' MODEL N0. F-17-GR g / 1 <br /> GROUND TO 3/4' 0 SOLID ROD DOUBLE ENTRY BOOT r COMPLIANCE PER ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES INCLUDING THE FILL AND VAPOR RISERS SHALL BE TESTED AFTER INSTALLATION AND =`� 0 <br /> CADWELD "L" CONNECTION "BRAVO" MODEL NO. i NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, NFPA 77, RECOMMENDED PERIODICALLY TO VERIFY BONDING AND GROUNDING COMPETENCY. v HAL P. GRUBB to <br /> (TYP.) EXTERNAL INTERNAL ; PRACTICE ON STATIC ELECTRICITY, NFPA 70, NATIONAL ELECTRIC CODE, AND THE <br /> F-17-GR 4 <br /> SUMP WALL SUMP WALL ' CALIFORNIA CODE OF REGULATIONS, SUBCHAPTER 15, PETROLEUM SAFETY THE MAXIMUM RESISTANCE FROM ANY FILL OR VAPOR ADAPTER TO THE BODY OF <br /> ORDERS-REFINING, TRANSPORTATION AND HANDLING, ARTICLE 5, FIRE AND THE GROUND ROD SHALL NOT EXCEED 10 OHMS FOR A METALLIC RISER PIPE, SPILL <br /> '-----------"'-----------"--------------'-------------------"------------------------------------ EXPLOSIONS. CONTAINMENT AND ADAPTER ASSEMBLIES. <br /> TYPICAL PENETRATION & CONNECTION DETAIL Q <br /> A: STATIC GROUNDING PLAN VIEW & BONDING DETAILS (SEE INSTALLATION SEQUENCE NOTES BELOW) PER SECTION 6.4.1 .3 OF NFPA 77, THE MEASURED TOTAL RESISTANCE IN THE THE RESISTANCE THROUGH ANY COMPOSITE OR NONMETALLIC STAGE I CONTAINMENT I V I v <br /> GROUND PATH TSHALL BE OF <br /> SCALE: NONE ADEEQUATE FORRELAXATONOFSTTATICECHARGE. THE MAXIMUM ALLOWABLE OGROUND M GIAOHMSATHESUMACOLLLEC VIER RESISTANCE OFCTHESEESEEMIRCONIDUC SEMI-CONDUCTIVE 10 OF CA4�F <br /> PATH TO EARTH RESISTANCE FOR STATIC ELECTRICITY GROUNDING APPLICATIONS ELEMENTS SHALL NOT EXCEED 100,000 OHMS. FOR THESE SYSTEMS, THE GROUND <br /> SHALL NOT EXCEED 100,000 OHMS. RESISTANCE TESTER MUST BE CONNECTED TO THE GROUND CONDUCTOR CONNECTION <br /> PER SECTION 6.4.1.3 OF NFPA 77, THE RESISTANCE IN METALLIC BONDING AND OR ON THE COMPOSITE CONTAINMENT SYSTEM OR RISER PIPE. <br /> GROUNDING SYSTEMS SHALL BE LESS THAN 10 OHMS. RESISTANCE HIGHER THAN 10 FOR INSTALLATIONS WITHOUT AN EXPOSED GROUND ROD CONNECTION, TOTAL SYSTEM <br /> --- 7 12" H-20 RATED ACCESS COVER OHMS INDICATES INADEQUATE CONNECTIONS. RESISTANCE SHALL BE MEASURED WITH A GROUND RESISTANCE TESTER BY A x <br /> A GROUNDING SYSTEM PER NEC CODE FOR CURRENT CARRYING CONDUCTORS SHALL QUALIFIED ELECTRICIAN FAMILIAR WITH GROUND TESTING. THE TWO POINT METHOD <br /> MAY BE USED WITH THE SITE ELECTRICAL GROUNDING AS THE SECOND TEST POINT. <br /> \ 3 CADWELD #4 WIRE CABLE TO GROUND ROD BE CONSIDERED MORE THAN ADEQUATE FOR A STATIC ELECTRICITY GROUNDING n <br /> 4" OR GROUND ROD CLAMP SYSTEM. THE NEC MAXIMUM GROUND PATH RESISTANCE FOR CURRENT CARRYING z <br /> MIN. PER THE NFPA 30, SECTION 5-6.3.4 ALL PARTS OF THE FILL PIPE ASSEMBLY, APPLICATIONS IS 25 OHMS. HOWEVER, GROUND ROD TO EARTH RESISTANCE UP TO <br /> INCLUDING THE DROP TUBE, SHALL FORM A CONTINUOUS ELECTRICALLY CONDUCTIVE 100 OHMS SHALL BE ACCEPTABLE FOR STATIC ELECTRICITY PROTECTION OF THE FILL <br /> DEVELOPMENT INFORMATION: o <br /> i 1/2" 0 X 10' LONG COPPER PATH. AND VAPOR RISERS. o <br /> 1 CLAD STEEL GROUND ROD IN 4" FILL AND THE MINIMUM WIRE SIZE FOR BONDING AND GROUNDING SHALL BE COPPER AWG #4 ARCO NTI <br /> NATIVE SOIL <br /> STAGE I RETURN A 1 2 0 BY 10' LONG COPPER CLAD STEEL GROUND ROD SHALL BE DRIVEN INTO <br /> PIPES (TMPD NATIVE SOIL ONLY. PLACING THE GROUND ROD INTO TANK PIT PEA GRAVEL SHALL MODIFIED o <br /> 2 #4 AWG STRANDED FILL SIDE NOT BE PERMITTED UNDER ANY CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR NOTE: <br /> WELDS W EXCEPTION OF FINAL CAD WELD @ GROUND ROD NOTED IN 3000 am/pm N <br /> BARE COPPER CONTAINMENT CONTAINMENT / <br /> CLEARING ANY UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF THE GROUND. SCHEDULE BELOW MAY BE PREFABRICATED OUTSIDE THE TANK AREA AND BROUGHT w/ 26x65 CAR WASH a <br /> GROUND WIRE TANK BOX (TYP ) TANK SUMP (TYP.) THE GROUND ROD TO GROUND WIRE CONNECTION SHALL BE ACCESSIBLE THROUGH A TO SITE. FUEL CANOPY w/ 8 MPD'S <br /> 2 4 H-20 RATED 12" DIAMETER MINIMUM ACCESS COVER TO ASSIST INSPECTION, N <br /> GROUND-ROD DETAIL TYp, FINISHED MAINTENANCE AND TESTING. THE SCREW TYPE GROUND ROD CLAMP SHALL BE UL SITE ADDRESS: <br /> (TYP.) ( ) LISTED FOR DIRECT BURIAL. o <br /> SURFACE TRINITY PARKWAY <br /> 0 o ONE MAIN STRANDED #4 THEIN CONDUCTOR SHALL BE RUN PAST EACH FILL SUMP. <br /> ONE STRANDED #4 THHN CONDUCTOR SHALL BE ROUTED TO EACH FILL SUMP. @ SCOTT CREEK DRIVE <br /> INSTALLATION AT SUMP SHALL BE AS FOLLOWS AND MUST BE COMPLETED IN ORDER STOCKTON,CA <br /> \ 6 \y\\/ NOTED AS FOLLOWS: - <br /> /\\///` 5 \ \\ <br /> 1 2" 0 X 10' LONG COPPER \/ 8 (gyp') \�/ FACILITY # TBD a <br /> CLAD STEEL GROUND ROD IN 1 \\\�\ -Yp \�\/ DESIGNED BY: ALLIANCE ZhAM: <br /> NATIVE SOIL \//\ (TYP.) \\�\ CHECKED BY: BP REPM: � <br /> UBLE DRAWN DY: W <br /> AANCE PM: � <br /> VERSION: PROJECT NO: c� <br /> WALL TANKS CD <br /> 16700 <br /> COIL STATIC GROUND WIRE CABLE 2 <br /> UP 3' & SECURE TO SIDE OFoRavnNc TITLE: <br /> o <br /> GALVANIZED STEEL RISER PEAGRAVEL <br /> BACKFILL <br /> TANK FILL&VAPOR RISER <br /> STATIC GROUNDING DETAILNX o <br /> (CALIFORNIA ONLY) D <br /> EARTH SHEET NO: <br /> (GROUND ROD INSTALLED IN SOIL NOT PEAGRAVEL BACKFILL) g <br /> NOTE: GAT2 <br /> ELECTRICAL CONDUIT, FUELING SYSTEM HARDWARE OR THE STATION ELECTRICALGROUNDING SYSTEM SHALL NOT BE USED FOR GROUNDING OR BONDING FILL AND <br /> B: STATIC GROUNDING SECTION & BONDING DETAILS VAPOR RISERS. i <br /> SCALE: NONE <br />
The URL can be used to link to this page
Your browser does not support the video tag.