My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2017 INSTALL PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10715
>
2300 - Underground Storage Tank Program
>
PR0541281
>
INSTALL 2017 INSTALL PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 4:35:43 PM
Creation date
11/6/2018 10:58:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2017 INSTALL PLANS
RECORD_ID
PR0541281
PE
2361
FACILITY_ID
FA0023650
FACILITY_NAME
Trinity Parkway AMPM ARCO #83819
STREET_NUMBER
10715
STREET_NAME
TRINITY
STREET_TYPE
Pkwy
City
Stockton
Zip
95219
APN
6602002
CURRENT_STATUS
01
SITE_LOCATION
10715 Trinity Pkwy
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\T\TRINITY\10715\PR0541281\2017 INSTALL PLANS.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLIENT: <br /> LOCATED IN MGR OFFICE LOCATED IN MGR OFFICE <br /> SECTION 1A SECTION 1A bp <br /> CPI PETRO PANEL. SEE BAR FOR ALL OTHER <br /> �—TERMINAL BLOCK WITHINISOLATED GROUNDCP <br /> 120V FOR MPD CONTACTOR DETAIL E THIS SHEET B REQUIRED ISOLATED <br /> COIL VOLTAGE WHICH IS MPD CONTACTORS <br /> ROUTED THROUGH GROUND CIRCUITS <br /> EMERGENCY STOP RELAY MPD MAINTINACE <br /> SWITCHUNTED ON PANEL <br /> FRONT OF CABINET 1A <br /> G <br /> FACTORY WIRING <br /> 00 - <br /> gull, <br /> FACTORY INSTALLED MPD CONTACTOR (TYP) TO TERMINAL 4:yl <br /> BLOCK <br /> El GN <br /> TERMINAL BLOCK WITHIN (PANEL G <br /> CPI PETRO PANEL. SEE NEUTRAL) FUELING PANEL "G <br /> DETAIL E THIS SHEET SUBMERSIBLE— w <br /> FACTORY WIRING BP WEST COAST PRODUCTS,LLC <br /> PAN <br /> MPD CONTACTORS ARE PID TERMINAL BLOCK WITHIN —T`T PANEL G _j <br /> PUMP CONTACTORS ARCO <br /> EL G <br /> PREWIRED BY CPI CPI PETRO PANEL. SEE 208Y/120V ESO RELAY <br /> FIELD INSTALLED DETAIL F THIS SHEET 100A MLO 100A MLO SUBMERSIBLE A <br /> POWER WIRING TO F PUMP PILOT <br /> LIGHTS <br /> DISPENSER (TYP.) <br /> M .5.3 33 <br /> B : MPD CONTACTORS SCHEMATIC DETAIL 0 <br /> 0 <br /> NOT TO SCALE: fV jFC C <br /> �4 � Ift ENG0"_ <br /> TERMINAL BLOCK WITHIN u ELECTRONIC EMERGENCY MPD MAINTENANCE <br /> CPI PETRO PANEL. SEE DISPENSER POWER FUELING STOP SWITCHES AND 18215 72ND AVENUE SOUTH <br /> DETAIL E THIS SHEET T ISOLATION RELAYS w IST CONTROLLERS EMERGENCY BYPASS KENT, WA 98032 <br /> SWITCHES FOR (425)251-6222 <br /> LOCATED BEHIND &. . . SEE DETAIL C THIS FUELING AND (425)251-8782 FAX <br /> 120V FOR SUBMERSIBLE FP ACCESS DOOR SHEET AND SCHEMATIC CIVIL ENGINEERING, LAND PLANNING, <br /> PUMP CONTACTOR COIL FACTORY WIRING —/ - LIGHTING LOCATED SURVEYING, ENVIRONMENTAL SERVICES <br /> cx <br /> I WIRING DIAGRAM ON <br /> VOLTAGE WHICH IS BEHIND ACCESS <br /> DETAIL <br /> E <br /> [Pio <br /> WIRING <br /> IrD <br /> FAC <br /> ROUTED THROUGH TO TERMINAL IST IST SHEET M.5.3.32 NO. DATE REVISION DESCRIPTION <br /> EMERGENCY STOP BLOCK I I DOOR <br /> RELAY GN ac 4D. OR OR 9-6-16 PERMIT SUBMITTAL <br /> -c ml_)� MAG 12-14-16-PERMIT RESUBMIT(PANEL G -cp 40. MAG <br /> FACTORY WIRING NEUTRAL) -clb 413- 1-31-17 PERMIT RESUBMITTAL <br /> ELECTRONIC DISPENSER - CONSTRUCIION RUASE <br /> ,Cb 8-16-17 <br /> FACTORY INSTALLED POWER ISOLATION RELAYS . --—--- <br /> SUBMERSIBLE PUMP 0 e LOCATED BEHIND ACCESS 11-14-17 REV. FOR CONSTRUCTION <br /> CONTACTOR COIL I JA PANEL G E ,—DEDICATED ISOLATED GROUND DOOR <br /> TO RS BOX 208Y/12OV LI 1�- <br /> 100A MILO , TERMINAL BAR FOR VFC'S GROUNDING <br /> LOAD _� BLOCKS FOR CONNECTION. MUST BE <br /> TERMINAL #1 rE <br /> SUBMERSIBLE PUMP SEE DETAIL D MPD POWER CONNECTED TO MAIN SERVICE <br /> CONTACTORS ARE PREWIRED THIS SHEET CONTROLS GROUND BY INSTALLING <br /> BY CPI <br /> CONTRACTOR <br /> " <br /> H TURBINE VARIBLE 42 <br /> SIGNk SPEED ELEVATION VIEW DOOR CLOSED SEAL: <br /> VFC CONTROLLER <br /> FACTORY WIRING # ,o� CONTROLLER <br /> STALLED ELEVATION VIEW DOOR OPEN <br /> WITHIN CPI PETRO <br /> PANEL NOT TO SCALE: 42 = <br /> P. GRUBB <br /> NOTES: 37, <br /> 676 <br /> FIELD INSTALLED 1. ALL DOORS HAVE LIFT OFF HINGES. 394 <br /> 2. ALL PANELBOARDS ARE CLEARLY LABELED WITH PANEL NAME TAG. <br /> POWER WIRING TO 3. ALL PANELBOARDS HAVE COMPUTER GENERATED CIRCUIT DIRECTORY CARDS LOCATED ADJACENT TO EACH PANEL. <br /> UNLEADED PUMP 1 4. ALL FEEDERS TO PANELBOARDS LOCATED WITHIN SYSTEM ARE FACTORY WIRED AS SPECIFIED. " V1 <br /> C. SUBMERSIBLE PUMP CONTACTORS SCHEMATIC DETAIL <br /> MOTOR (TYP.) 5. AL105 <br /> L CONTROLLED LIGHTING LOADS ARE FACTORY WIRED FROM CIRCUIT BREAKER TO LINE SIDE OF CONTACTOR. REFER TO SECTION 1A STUB UP AREA OF' CA. <br /> MANUFACTURERS SHOP DRAWINGS FOR ADDITIONAL INFORMATION. <br /> 6. ALL CONTROLLED FUEL SYSTEM LOADS ARE FACTORY WIRED FROM CIRCUIT BREAKER TO LINE SIDE OF CONTACTOR. E <br /> NOT TO SCALE: REFER TO MANUFACTURERS SHOP DRAWINGS FOR ADDITIONAL INFORMATION. <br /> X <br /> ELECTRONIC DISPENSER POWER ISOLATION RELAYS z <br /> REFER TO DIP SWITCH CHART FOR ACTUAL SETTINGS <br /> INPW IMP SWffCNES BIPUf DIP SWMiES INPUT MP SNDDNM INPUT DIP 58NCN13 oRS BOX DETAIL A: FUEL SYSTEM PANEL PLAN & ELEVATIONS PLAN VIEW <br /> AA <br /> -------- ------ 00 (PREWIRED BY CPI) <br /> :-------- -------- NOT TO SCALE: <br /> :oc-.vevava :oveoavvv----- <br /> 1/4 MP DEVELOPMENT INFORMATION: <br /> mm <br /> 6 7 8 9 10 11 12 13 <br /> ElElElEIDE1 INTERNAL FACTORY WIRING INTERNAL FACTORY WIRING ARCO NTl0' <br /> 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 7 8 1 <br /> ** 70 *❑0* 1 MODIFIED <br /> 1 EIE:1[_IL1L30E:IE:l L10E:IE:IL]LIEIE:I <br /> 3000 am/pm <br /> 0 0 0 0 0 0 w <br /> 26'x65' CAR WASH <br /> FACTORY WIRING TO <br /> MOON 00000000 00000000 00000000 LINE 8 Ll OD W/ <br /> 1 2 3 4 5 6 7 Z <br /> ow N. mw 0 0 x o w � m m FUEL CANOPY W/ 8 MPD S <br /> 0 0 zo <br /> 0 0 8 ow 8 <br /> Zco 0 SITE ADDRESS: <br /> B R 9 <br /> z <br /> L E 0 0 0 <br /> R <br /> D 0 0 <br /> m <br /> TRINITY PARKWAY <br /> 0 0 <br /> rn <br /> p PI e > > <br /> 0 < , , I <br /> 7= z <br /> BCDEFGHJ BCDEFGHJ BCDEFGHJ BCDEFGHJ TERMINAL BLOCK FP <br /> I 7Ty77 7 17171717171717177) <br /> INTERNAL ESO FACTORY WIRING <br /> LOAD 120V FOR RS BOX �jl zzzf==f==fzzzl @ SC01T CREEK DRIVE <br /> 8 NG FP WHICH IS ROUTED �p <br /> STOCKTOKCA900 - 0 w <br /> L7 THROUGH EMERGENCY E <br /> 1234567 <br /> :%ODD <br /> =77 7 7777777777- 77- 77 777777777777 6 STOP RELAY FACTORY 0 0Q) (7 0 <br /> 000000©© 0 (0) 0 00;DO DO 0:0)0 0),OD 0 00 0:0)03 0 0 )0 OD(0) D OD 0(0)0 0 00) (Z 0 (07b) 00) <br /> WIRED :2�)0)0 0)03 FACILITY # TBD <br /> PE <br /> FACTORY WIRING <br /> H TO TERMINAL <br /> BLOCK D1-2 FACTORY WIRING 0 Do 00 00 01 1_ _01)Do 0 D 0 Do-0,1)OD OD OD 0(--Z--)),-0),0 00 0_011 0 D D -0) :03:0)_01 D 0 Do 100 0 DESIGNED BY:0 <br /> T T S2 "CKM BY: BP REPM: <br /> TO TERMINAL <br /> FACTORY FACTORY FACTORY J, IL. 1 12 1 Z� 1 8 <br /> WIRING TO WIRING TO WIRING TO BLOCK IG DRAWN BY: ALLIANCE <br /> TERMINAL TERMINAL TERMINAL rk VERSION: PROJECT NO: <br /> BLOCK #1 FACTORY 'TI I I _q <br /> BLOCK Dl—1 WIRING TO T I I I I I I ITT'T '11 " 0 - <br /> BLOCK SWN T 9� 9� 5 16700 <br /> TERMINAL cd <br /> �z 9 !z I !R 4� INTERNAL ESO FACTORY WIRING <br /> BLOCK GN 5 vl� Q 5 DRAWNG TITLE: <br /> NOTES: !;2 1 t� X <br /> CO <br /> �2 <br /> 1. REFER TO DISPENSER INSTALLATION DIAGRAMS FOR TERMINATION LABELING. ESO AND RESET <br /> ELECTRICAL PANEL POWER <br /> FIELD WIRING TO <br /> 2 <br /> AND CONTROL WIRING DETAILS <br /> 2, ALL FIELD WIRING TERMINALS MUST BE WIRED WITH A MINIMUM INSULATION RATING OF 60°C. 0 <br /> R R R <br /> z z m CASHIER CONTROL <br /> FROM EACH DISPENSER TO THE GROUND BAR z z z z aw z z z z z z z z z z <br /> 3. WIRING IS TYPICAL OF ALL DISPENSERS. GROUND CONDUCTOR #12AWG MUST BE RUN 0 <br /> PANEL <br /> OF THE DISPENSER/PUMP PANEL. <br /> p SHEET NO: <br /> ) UFACTURER'S R WIRING LEGEND <br /> F�AC) AND DATA(DC) ARE TYPICALLY RUN IN SEPERATE CONDUITS, HOWEVER, DISPENSER MAN <br /> 4. DISPENSER PUMP POWER <br /> INSTRUCTIONS SHOULD BE LLOWED. mE <br /> FIELD WIRING TO FACTORY WIRING <br /> 5. ALL VARIABLE FREQUENCY CONTROLLER WIRING MUST BE ROUTED SEPERATELY FROM ALL OTHER WIRING DUE TO ELECTRICAL NOISE <br /> VEEDER ROOT PANEL — FIELD WIRING <br /> CREATED BY THE CONTROLLERS. FIELD WIRING TO DISPENSERS <br /> M ,5132 <br /> D: ELECTRONIC DISPENSER POWER ISOLATION RELAYS SCHEMATIC DETAIL E : TYPICAL FUELING CENTER AT TERMINAL BLOCKS <br /> NOT TO SCALE: NOT TO SCALE: U <br />
The URL can be used to link to this page
Your browser does not support the video tag.