Laserfiche WebLink
STATE OF C INLIFORNIQ WATER RESOURCES CONTROL - ")ARD <br /> FORM `B': UNDERGROUND STORAGE TANK PROCA,AM <br /> TANK TANK PERMIT APPLICATION INFORMA' ON <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 3W<RMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION TAN � <br /> ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM INTERIM PERMIT ❑4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE <br /> ❑6 TANK REMOVED U <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ®,y N <br /> 3 HBO /v//hf2iW-FARM TANK-YES❑ NO ❑ (J� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY o <br /> A. OWNERS TANK ID# B. MANUFACTURED BY <br /> (Q <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A, ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED ❑3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#' <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK <br /> MATERIAL F75 CONCRETE El6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR F-] I RUBBER LINED ❑ 2 ALKYD LINING F-]3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLENEWRAP ❑2 TARORASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHEA <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZEDSTEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> PI <br /> 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S I PRECISION TESTING P 8 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# r / /\ TTAA1NK ID# <br /> m = / 7 7 v v <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> e{ J /DSk <br /> i PERMIT NUMBER PERMIT APPROVAL DATEPERMIT E% RATION DATE <br /> 1� Q / <br /> I� CHECK# PERMIT AMOUNT I SURCHARGE AM FEE CODE IPT# BY: <br /> FORM a(s-z9-ea) THIS FORM MUST BE ACCOYPANIE - A FACILITY/SITE APPLICATION, FORM `A',UNLESS A ENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />