Laserfiche WebLink
California Environmental Reporting System(CERS) Underground Storage Tank-Tank Information <br /> acility/Site <br /> CERS In <br /> ART CONTAINER CORP 1018 <br /> 400 VICTOR RD 10181325 <br /> ODI,CA 95240 ' Ill••• 1 JN <br /> [object <br /> bmittal Status <br /> mitted on 11/4/2015 by Gloria Suarez of DART CONTAINER CORP(LODI,CA) <br /> mittal was Accepted;Processed on 11/30/2015 by NG,WILLY for San Joaquin County Environmental Health <br /> mments by regulator:This UST submittal was received but not reviewed by Willy Ng,REHS,ICC Certified UST Inspector,on November 30,2015. This submittal is <br /> to verification at the next scheduled field inspection. <br /> ype of Action(UST Tank) <br /> onfirmed/Updated Information <br /> ART CONTAINER CORP <br /> 400 VICTOR RD <br /> ODI,CA 95240 <br /> ank loot Date UST System Installed Tank Configuration <br /> A0195102 4/25/1986 A Stand-alone Tank <br /> ank Manufacturer Date Existing UST Discovered Number of Compartments in the Unit <br /> TOCKTON MFG 1 <br /> ank Capacity In Gallons Date UST Permanently Closed Additional Description <br /> 0000 <br /> 4' <br /> ank Use Tank Contents ype of Tank <br /> ther Diesel 0uble Wall <br /> OILER FUEL Other Petroleum Contents rimary Containment Secondary Containment <br /> teel Other <br /> Other Non-Petroleum Contents Fiberglass Coated Steel <br /> verffll Protection <br /> Audible/Visual Alarms Yes Fill Tube Shut-Off Valve <br /> Ball Float Exempt <br /> roduct/Waste Piping Construction <br /> ping Construction Primary Containment Secondary Containment Piping/Turbine Containment Sump <br /> Double-walled I Steel Steel None <br /> iping System Type <br /> 3 CCR§2636(a)(3)Suction <br /> Vent,Vapor Recovery(VR)and Riser/Fill Pipe Piping Construction <br /> Primary Containment Vapor Recovery Primary Containment Riser Pipe Primary Containment Vent Piping Transition Sumps <br /> Steel None Steel None <br /> Fill Components Installed <br /> Secondary Containment Vapor Recovery Secondary Containment Riser Pipe Secondary Containment yes Spill Bucket <br /> Steel None None yes Striker Plate/Bottom Protector <br /> Containment Sump <br /> nder Dispenser Containment(UDC) orrosion Protection <br /> onstruction Type Construction Material Sacrificial Anode <br /> o Dispensers None Impressed Current <br /> es Isolation <br /> �pplicant Certification €x <br /> pplicant Name Applicant Title Date Certified <br /> LORIA SUAREZ SAFETY LEADER <br /> Printed on 12/2/2015 10:34 AM <br />