My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2007 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2300 - Underground Storage Tank Program
>
PR0231951
>
BILLING 2007 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 11:15:46 AM
Creation date
11/6/2018 11:54:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2007 - 2015
RECORD_ID
PR0231951
PE
2361
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\V\VICTOR\1400\PR0231951\BILLING 2007 - 2015.PDF
QuestysFileName
BILLING 2007 - 2015
QuestysRecordDate
6/2/2016 4:24:00 PM
QuestysRecordID
3102297
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Environmental Reporting System (CERS) Underground Storage Tank-Monitoring P a <br /> acility/Site <br /> iDART CONTAINER CORP Cl Rs m <br /> 11400 VICTOR RD 10181325 <br /> ODI,CA 95240 UST Tank N <br /> TA0195102 <br /> Pipe Monitoring is Performed Using the Following Method(s) <br /> Continuous Monitoring of Piping Secondary Containment <br /> Piping Secondary Containment Panel Manufacturer Leak Sensor Manufacturer <br /> Panel Model If Leak Sensor Model N <br /> Leak Alarm Triggers Automatic Pump Shutdown <br /> Failure/Disconnect Triggers Pump Shutdown <br /> Mechanical Line Leak Detector Performs 3 GPH Leak Test <br /> MLLD Manufacturer MLLD Model <br /> Electronic Line Leak Detector Performs 3 GPH Leak Test <br /> LLD Manufacturer ELLD Programmed In-Line Testing ELLD Triggers Automatic Pump Shutdown <br /> LLD Model ELLD Failure/Disconnect Triggers Automatic Shutdown <br /> Pipeline Integrity Testing Yes Visual Pipeline Monitoring <br /> Pipeline Integrity Testing Frequency Visual Pipeline Monitoring Frequency <br /> Minimum Monthly <br /> Yes Suction Piping Meets Exemption Criteria <br /> No Regulated Piping Per Health and Safety Code,Division 20,Chapter 6.71s Connected To The Tank System <br /> Yes Other Pipeline Monitoring <br /> MONTHLY INSPECTIONS BY CERTIFIF D UST OPERATOR <br /> der Dispenser Containment(UDC(Monitoring <br /> OC Monitoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br /> o Dispensers <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown <br /> DC Panel Manufacturer <br /> Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br /> DC Panel Model If <br /> UDC Monitoring Stops Flow of Product at Dispenser <br /> DC Leak Sensor Manufacturer <br /> UDC Construction <br /> DC Leak Sensor Model <br /> UDC Secondary Containment Monitoring <br /> Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br /> eriodic System Testing <br /> ELD Testing <br /> ¢s Secondary Containment Testing <br /> as <br /> Sill Bucket Testing _ <br /> Printed on 12/2/2015 30:35 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.