Laserfiche WebLink
LEAK TEST METHOD OUTPUT RELAY SETUP _ APR 0 12016 - -- ' <br /> TEST ON DATE ALL TANK - - - - - - - - _ _ _ <br /> OCT 9, 2008 <br /> START TIME : DISABLED R 1 :87 UNL '3000 <br /> TEST RATE :0.20 GAL/,HR TYPE: <br /> DURATION 2 HOURS PUMP CONTROL OUTPUT <br /> TANK #: 6 <br /> TST EARLY STOP:DISABLED VPPS LODI <br /> LEAH TEST REPORT FORMAT 1N-TANK ALARMS 931 E VICTOR RD <br /> NORMAL T 6:HIGH WATER ALARM <br /> T 6:LOW PRODUCT ALARM <br /> LIQUID SENSOR ALFIS MAR 23. 2016 4:41 PM <br /> L 3:FUEL ALARM <br /> L I :SENSOR OUT ALARM <br /> L 3:SENSOR OUT ALARM SYSTEM STATUS REPORT <br /> L I :SHORT ALARM _ - - - - - " _ _ - - - . <br /> L 3:SHORT ALARM T 3:LOW PRODUCT ALARFI <br /> R 2:87 OWL T 3:DELIVERY NEEDED <br /> TYPE: <br /> LIQUID SENSOR SETUP PUMP CONTROL OUTPUT. <br /> - - - - - - - - _ - - _ TANK #: 7 INVENTORY REPORT' <br /> L I :ANNULAR <br /> TRI-STATE 114-TANK ALARMS T i :DFR <br /> CATEGORY ANMl1ULAL(SINGLE T 7:HIGH WATER ALARM VOLUME - 6306 GALS <br /> FLOAT)k SPACE T 7:LOW PRODUCT ALARM ULLAGE = 5477 GALS <br /> LIQUID SENSOR ALMS 90% ULLAGE= 4298 GALS <br /> L 2:87 STP28LIMP L 2:FUEL ALARM TC VOLUME 6311 GALS <br /> L I :SENSOR OUT ALARM HEIGHT = 49.96 INCHES <br /> TRI-STATE (SINGLE FLOAT) WATER VOL = 0 GALS <br /> CATEGORY : STP SUMP L 2:SENSOR OUT ALARM WATER = 0.00 INCHES <br /> L ] :SHORT ALARM TEMP = 58.9 DEG F <br /> L 2:SHORT ALARM <br /> L 3:87 STPISUMP <br /> TRI-STATE (SINGLE FLOAT) - T 2:DFQL �- <br /> CATEGORY STP SUMP VOLUF4f = 2577 GALS <br /> ULLAGE = 9206 GALS <br /> 90% ULLAGE= 8027 GALS <br /> TC VOLUME = 2578 GALS <br /> HEIGHT - 25.48 INCHES <br /> - - - WATER VOL = 0 GALS <br /> WATER = 0.00 INCHES <br /> TEMP - 56.3 DEC F <br /> SMARTSENSOR SETUP <br /> - - - - - _ - - .. _ _ _ T 3:DFR <br /> VOLUME = 551 GALS <br /> s I :CCVP ULLAGE 11232 GALS <br /> PUMP SENSOR SETUP CATEGORY VAPOR VALVE 90% ULLAGE= 10053 GALS <br /> s 2:VAPOR PRESSURE SENS TC VOLUME HEIGH - 549 GALS <br /> S 1':87 OWL CATEGORY VAPOR. PRESSURE WATER TVOL = e 60 GALS <br /> ES• <br /> TANK 9: 6 WATER = 0.00 INCHES <br /> DISPENSE MODE: s 8:ATM PRESSURE SENSOR TEMP - 68.5 DEG F• <br /> MANIFOLDED: ALTERNATE CATEGORY ATM P SENSOR <br /> S 2:87 OWL T 4:DFL <br /> TANK a: 7 VOLUME = 6095 GALS <br /> DISPENSE MODE: ULLAGE - 5686 GALS <br /> MANIFOLDED: ALTERNATE 90Y. ULLAGE- 4509 GALS <br /> TC VOLUME = 6091 GALS <br /> HEIGHT - 48.58 INCHES <br /> WATER VOL 13 GALS <br /> LATER 0.66 INCHES <br /> TEMP 61 . 1 DEG F <br /> PMC SETUP T 5:DFL <br /> VOLUME = 5931 GALS <br /> PMC VERSION: 01 .02 ULLAGE = 5852 GALS <br /> VAPOR PROCESSOR TYPE 90% ULLAGE= 4673 GALS <br /> VAPORo ROCS SO 1RHER TC VOLUME = 5921 GALS <br /> ll�VIVHEIGHT - 47.51 INCHES <br /> WATER VOL = 0 GALS <br /> -WATER = 0.00 INCHES <br /> TEMP - 63.7 DEG F <br />