San Joaquin County low <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone:(209)468-3420 Fax:(209) 468-3433 Web:www.siaov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facdtty Address: Date: <br /> ACIFIC LODI PLANT&CARDLOC'i 1 130 E VICTOR RD LODI <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump o V ❑R o COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi n V ❑R o COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V oft ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 327 CCR 2535(b)(2) Overfill prevention was overridden ❑V ❑R o COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R o COS <br /> 329 CCR 2717.1(g) Tampered with red tag ❑V ❑R n COS <br /> 330 CCR 2717.1(f) Deposited petroleum Into a red tagged UST o V ❑R ❑COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms o V ❑R ❑COS <br /> 332 CCR 2631.1 USTsystem not compatible with the substance stored ❑V ❑R o COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R n COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements o V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed n V oft ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(preJanuary 1984) o V o R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V o R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plot/Plan map was not submitted. The 3-22-16 at 913 PM lists the 87(2) tank <br /> mechanical line leak detector as a FX1 V. This tank actually has a VMI 99LD2000 leak detector. A site plan must be <br /> submitted identifying the locations where monitoring will be performed. During the inspection Mike Eliason uploaded <br /> an updated UST Monitoring Site Plan listing the 87(2)tank mechanical line leak detector as a VMI 99LD2000. <br /> Continue to log into the California Environmental Reporting System(CERS) at httpl/cers.calepa.ca.gov/and upload a <br /> copy of the UST Monitoring Site Plan as changes occur. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Page 3 of 5 <br />