Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 23, California Code ofRegulatidns <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or re ort must r 216 <br /> monitoring system control Panel by the technician who performs the work. A copy of this form must be provided to the tank system o o er t <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> FacilityName: VALLEY PACIFIC CARDLOCK#152 Bldg.No.: <br /> Site Address: 930E VICTOR ROAD City: LODI Zip: 95240 <br /> Facility Contact Person: MIKE ELIASON Contact Phone No.: (209)948.9412 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Servicing: 3/23/2016 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: T6 87 Tank ID: T7 87 <br /> Z In-Tank Gauging Probe. Model VR MAG PLUS Z In-Tank Gauging Probe Model VR MAG PLUS <br /> Z Annular Space or Vault Sensor. Model VRA20 Z Annular Space or Vault Sensor Model VR 420 <br /> Z Piping Sump/Trench Sensor(s) Model VR 208 Z Piping Sump/Trench Sensor(s) Model VR 208 <br /> ❑Fill Sump Sensor(s) Model ❑Fill Sump Smsor(s). Moder <br /> Z Mechanical Line Irak Detector Model LD2000 Z Mechanical Line Leak Detector Moder LD2000 <br /> ❑Electronic Line Leak Detector. Model ❑Electronic Line Leak Detector Model <br /> Z Tank Overfill/High-Level Sensor Model FLAPPER VALVE ®Tank Overfill/High-Level Sensor Model FLAPPER VALVE <br /> ❑Other(specify equipment type and model in Section E on Page 2) ❑Other(specify equipment type and model in Section E on Page 2) <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe Model- ❑In-Tank Gauging Probe. Model <br /> ❑Annular Space or Vault Sensor Model ❑Annular Space or Vault Sensor Model <br /> [I Piping Sump/Trench Sensor(s) Model: El Piping Sump/Trench Sensor(s). Model <br /> ❑Fill Sump Sensor(s) Model ❑Fill Sump Sensor(s). Model <br /> ❑Mechanical lane Leak Detector Model ❑Mechanical Line teak Detector Model <br /> ❑Electronic Line Leak Detector Model. ❑Electronic Line Leak Detector Model. <br /> ❑Tank Overfill/High-Level Sensor Moder ❑Tank Overfill/High-level Sensor Model <br /> ❑Other(specify,equipment type and model in Section E on Page 2) ❑Other(specify equipment type and model in Section E on Page 2) <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> ❑Dispenser Containment Sensor(s). Model. ❑Dispenser Containment Sensor(s). Model <br /> ®Shear Valve(s) Z Shear Valve(s) <br /> ®Dispenser Containment Float(s)and Cham(s) Z Dispenser Containment Float(s)and Cham(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Semor(s) Model, ❑Dispenser Containment Sensor(s) Model <br /> ❑Shear Valve(s) ❑Shear Valves) <br /> ❑Dispenser Containment Float(s)and Cham(s) ❑Dispenser Containment Float(s)and Cham(s). <br /> Dispenser ID- Dispenser 1D: <br /> ❑Dispenser Containment Sensor(s). Model ❑Dispenser Containment Sensor(s) Model <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Floats)and Chaints). ❑Dispenser Containment Floats)and Chain(s) <br /> +If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): RICHARD THOMAS Signature: 1.—a. <br /> Certification No.: 5012133701 License.No.: 803705 <br /> Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATION Phone No.:(707)779-4999 <br /> Testing Company Address: P.O.BOX 5850,RIVERSIDE, CA 92517-5850 Date of Testing/Servicing: 3/23/2016 <br />