0 <br />0 <br />SAN JOAQUI N LOCAL HFAlYrH DISTRICT <br />TANK CLOSURE PLAN REVIEW CHECKLIST - MINIMUM VERIFICATION LAB ANALYSES <br />TANK <br />TANK CONTENTS <br />TPH -G <br />TPH-D <br />TEPH <br />BTX&E <br />CL HC <br />TEL <br />EDB <br />H S) <br />METALS <br />(ICP- <br />PCB <br />(8270) <br />ID # <br />Waste Product <br />��(5030) <br />GC -FID <br />GC -FID <br />(3550) <br />(8020) <br />(8010) <br />(D <br />AES) <br />(8080) <br />(5030) <br />(3540) <br />- <br />(8240) <br />- <br />i� <br />LEADED GASOLINE <br />------- <br />X <br />%� <br />-UNL GASOLINE <br />---. <br />---DIESEL <br />--- <br />--- <br />- <br />-- __---.-- <br />-- <br />-- <br />----- <br />--KEROSENE <br />--. <br />UNKNOWN FUEL <br />SSSS- <br />-OIL <br />a------.--SSSS-SSSS-- <br />_SSSS <br />CHLOR SOLVENTS <br />NONCHLOR. SOLVTS <br />-.ROSS..._..__.....-SSSS-- <br />WASTE/USED OIL <br />--SSSS-- <br />----- <br />MINIMUM VERIFICATION LABORATORY ANALYSES TERMINOLOGY <br />The following listing of laboratory analyses abbreviations is provided as a guide so that <br />terminology used will be more familiar. All analyses methods are designated EPA methods as <br />described in EPA SW 846, Third Edition. Those methods not found in SW 846, are <br />specifically noted. <br />TPH G Total Petroleum Hydrocarbon, Gasoline <br />TPH D Total Petroleum Hydrocarbon, Diesel <br />TEpH Total Extractable Petroleum Hydrocarbon (8015) <br />BTX 6 E (8020) Benzene, Toluene, Xylene 6 Ethyl Benzene (8020) <br />CL HC 8010 OR 8240 Chlorinated Hydrocarbon 8010 or 8240 <br />TEL (DOHS-LUFT) Tetraethyl Lead (DOHS-LUFT) <br />EDB (DOHS -AB 1803) Ethylene dibromide (DOHS -AB 1803) <br />GC FID Gas Chromatoggraphy Flame Ionization Detector <br />ICP -AES OR AA Inductively Coupled Plasma Atomic Emission Spectrometry or Atomic <br />Absorption Spectrometry <br />Method 5030 Purge and Trap Sample Preparation <br />Method 3550 Sonication Sample Preparation <br />Method 3540 Soxhlet Sample Preparation <br />QA/QC Quality Assurance/Quality Control <br />Notes: To avoid false positive detection of benzene, benzene -free solvents are to be used. <br />Fused capillary columns are preferred to packed columns; a packed column may be used as a <br />"first cut" with "dirty" samples or once the hydrocarbons have been characterized and <br />proper QA/QC is followed. <br />For Drinking Water Sources' <br />PA recommends that the 500 series for volatile <br />organics be used in preference to the 600 series because the detection limits are lower and <br />the QA/QC is better. <br />/ <br />SITE ADDRESS/2 SWEEPS # <br />CONTRACTOR \J/tel 71�4�P�� 0 / C- APPROVAL DATE <br />