Laserfiche WebLink
SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> 304 E.Weber Ave.,Third Floor•Stoc]¢on,.CA 9520 2708• Phone(209)468-3420 <br /> Donna Haan,RE:H.S.,Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program. PerilPermit <br /> Record m Number Program Code and Description Valid <br /> PRO523950 PT0016320 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/1/2006 To 12/31/2006 <br /> Hazardous Waste Generator Program: <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20,Chap.6.5,Art.2-13, <br /> Sec,25100 at seq,_and Title 22,Califomia Code-of Regulations,Chap_20, _ <br /> PRO521738 2300-UNDERGROUND STORAGE TANK FACILITY 1/112006 To 12131/2006 <br /> Undemround Storage Tank Program: <br /> California Health and Safety Code,Div_20,Chap._6.7 and Title 23,California_Code of Regulations,Chap, 16._________ ...................................... <br /> P/E -Tank# Tank Record m Permit# Capacity Contents Permit Status System Type Leak IJetec[ion <br /> 2372 . 1 390005217380515689 PT0014690 20,000 REGULAR UNLEADED Active,billable DOUBLE WALLED continuous Interstitial htonit., <br /> 2370 2 390005217380515690 PT0014691 8,000 DIESEL Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2370 3 390005217380515691 PT0014692 12,000 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain the operating pernit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions <br /> established by San Joaquin County. <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the PerrmMe shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) written Monitoring Procedures and an Emergency Response Plan most be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved <br /> monitoring,response,and plot plans shall be maintained onsite with the permit <br /> 5) The Perndmce shall comply with the monitoring procedures referenced in this permit. <br /> -6) The Permimce shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> 7), In the event of a spill,leak,or other unauthorized relwse,the Permitee shall comply with the requirements of Title 23 CCR,Chap.16,An.5,and the approved Emergency Response Plan. <br /> g) Writum records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was <br /> performed. <br /> - 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 11) Construction,repair and/or removal pemnts are required from the EHD prior to any change,repair or removal of UST system equipment. <br /> 12) The Permittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of the date of the issuance of this permit. <br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. <br /> '14) A"Conditional"Permit .maybe revoked if corrections specified on the inspection report are not completed by the date(s) indicated. <br /> PERMITS TO OPERATE are NOT TRANSFERABLE <br /> and may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: JD SINGH SERVICE STATIONS, INC <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility: UNOCAUSUBWAY Facility ID FA0014762 <br /> 9015 W WALNUT GROVE Account ID AR0025117 <br /> THORNTON CA 95686 Issued 2/3/2006 <br /> Billing Access: ATTN : JD SINGH SERVICE. STATIONS, INC <br /> JD SINGH SERVICE STATIONS, INC <br /> 2410 TECADO TERRACE <br /> FREMONT CA 94539 <br /> M23.rpt <br />