Laserfiche WebLink
.)NlFiED PROGRAM CONSOLIDATED Fr 'M <br /> TANK <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Chea all that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE N 1.PRESSURE ❑2.SUCTION 0 3.GRAVITY 458 0 1.PRESSURE [12. SUCTION 0 3.GRAVITY 459 <br /> CONSTRUCTION] ❑1.SINGLE WALL 0 3.LINED TRENCH 0 99.OTHER 460 [11.SINGLE WALL 0 95.UNKNOWN 462 <br /> MANUFACTURER N 2.DOUBLE WALL 0 95.UNKNOWN 0 2.DOUBLE WALL 0 99.OTHER <br /> MANUFACTURER Smith Red Thread II 461 MANUFACTURER 463 <br /> 0 L BARE STEEL N 6.FRP COMPATIBLE wH00% METHANOL 0 1.BARE STEEL 0 6.FRP COMPATIBLE W1100%METRA l <br /> 0 2.STAINLESS STEEL 0 7.GALVANIZED STEEL 0 UKNOWN 0 2. STAINLESS STEEL 0 7.GALVANIZED STEEL <br /> 0 3.PLASTIC COMPATIBLE W1 CONTENTS 0 99. OTHER 0 3. PLASTIC COMPATIBLE WI CONTENTS 0 B.FLEXIBLE(HOPE) 0 99. OTHER <br /> 0 4.FIBERGLASS 0 8.FLEXIBLE(HDPE) [14. FIBERGLASS 0 9.CATHODIC PROTECTION <br /> 0 5.STEEL WICOATING 0 9.CATHODIC PROTECTION 464 0 5. STEEL W/COATING 0 95.UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check a6 that appy)(A description of the monitoring program shall be submitted to the local agers y.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 4% SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Checka8 matepPlyk PRESSURIZED PIPING(Check an mat apply): <br /> 01. ELECTRONIC LINE LEAK DETECTOR 30 GPH TEST WITH AUTO PUMP SHUT OFF FOR 01. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION.AUDIBLE AND VISUAL <br /> ALARMS. ALARMS. <br /> [12. MONTHLY 0.2 GPH TEST 02. MONTHLY 0.2 GPH TEST <br /> 03. ANNUAL INTEGRITY TEST(0,1GPH) ❑3. ANNUAL INTEGRITY TEST(O.IGPH) <br /> 04. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check m that apply) <br /> 05. DAILY VISUAL MONITORING OF PUMPING SYSTEM-TRIENNIAL PIPING INTEGRITY 05. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): ❑6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> ❑7. SELFMONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW 07. SELFMONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Ched,al tiatyply): <br /> ❑8. DAILY VISUAL MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that appy): PRESSURIZED PIPING(Check ell that apply). <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check oral (Civx*one) <br /> Na. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS Oa AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> [1b. ALTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> Oc. NO AUTO PUMP SHUT OFF Oc NO AUTO PUMP SHUT OFF <br /> N 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUTOFF OR 011, AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> 012. ANNUAL INTEGRITY TEST(0.1 GPH) 012. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTIONIGRAVITY SYSTEM <br /> 013. CONTINUOUS SUMP SENSOR.AUDIBLE AND VISUAL ALARMS 013. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Chea,all mat appy) EMERGENCY GENERATORS ONLY(Check all mat apply) <br /> 014. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND 014. CONTINUOUS SUMP SENSORTWI HOUT AUTO PUMP SHUT OFF*AUDIBLE AND <br /> VISUAL ALARMS VISUAL ALARMS <br /> 015. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR 015. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> 016, ANNUAL INTEGRITY TEST(0.1 GPH) 016. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 017. DAILY VISUAL CHECK 017. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER <br /> CONTAINMENT 0 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE [14.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 02. CONTINUOUS DISPENSER PAN SENSOR.AUDIBLE AND VISUAL ALARMS 05.TRENCH LINER I MONITORING <br /> August 23 03, CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+ 0 6.NONE 469 <br /> AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> loss that the ormation provided is two aM accurate to the best of mY knowledge. <br /> SIGJATYEHE OF OWNE OPE DATE 470 <br /> 7- /- Oa- <br /> NAME OF O R7 PRATOR(print) TITLE OF OWNERIOPERATOR 472 <br /> Craig B nt I Project Manager, Fillner Construction, Inc. <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) Penni)Expiration Dale(For local use only) <br /> 475 <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br />