My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2201
>
2300 - Underground Storage Tank Program
>
PR0231282
>
BILLING 1985-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2021 10:59:25 PM
Creation date
11/7/2018 8:31:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-2000
RECORD_ID
PR0231282
PE
2381
FACILITY_ID
FA0003909
FACILITY_NAME
PORT OF STOCKTON
STREET_NUMBER
2201
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503001
CURRENT_STATUS
02
SITE_LOCATION
2201 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WASHINGTON\2201\PR0231282\BILLING 1985-2000.PDF
QuestysFileName
BILLING 1985-2000
QuestysRecordDate
8/16/2017 4:58:49 PM
QuestysRecordID
3583937
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• STATEOFCAUFORNA % ���; <br /> STATE WATER RESOURCES CONTROL BOARD + <br /> AMARKUNDERGROUND STORAGE TANK PERMIT APPLICATION• FORM B 3.,,, o°COMPLETE A SEPARATE FORM FOR TANK SYSTEM.ONLY I NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ A AMENDED PERMIT ❑ 8 TEMPORARY TANK CLOSURE 8 TANK R ED <br /> v <br /> CBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.A B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) 0. TANK CAPACITY IN GALLONS: <br /> ILTANK NTENTS IFA-1 ISMARKED.COMPLE I E ITEM C. <br /> � to REGULAR 3 DIESEL 6AVIATION GAS <br /> A 1 MOTOR VE4ICLE FUEL 'J A OIL 8. C. ❑ UNLEADED s GASAHOL <br /> ❑ 2 PETROLEUM ❑ W EMPTY I I PRODUCT ❑ lb PREMIUM T METHANOL <br /> UNLEADED 5 JET FUEL <br /> 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN I ❑ 2 WASTE ❑ 2 LEADED 99 OTHER (DESCRIBE IN ITEM D. SELCWI <br /> 0. :F(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED / ——q C.A.S.a: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,a.AND C.AND ALL T4AT APPLIES IN BOX C AND <br /> — 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> A. TYPE OF <br /> SYSTEM ❑ 2 SINGLE WALL ❑ A SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> 11 1 BARE STEEL j❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ A STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC <br /> B. TANK j g pOLWINYI CHLORIDE ❑ T ALUMINUM ❑ 8 100% METHANOL COMPATIBLE WIFRP <br /> MATERIAL !_ 5 CONCRETE <br /> (PrimaryTank) Ji 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN IJ 99 OTHER <br /> 1 RUBBER LINED 2 ALKYD LINING ❑ 3 EPDXY UNING ❑ A PHENOLIC LINING <br /> C.INTERIOR �❑ 5 GLASS LINING I a UNLINED ❑ % UNKNOWN U 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100Y. METHANOL? YES_ NO_ <br /> O.CORROSION 1 POLYETHYLENE WRAP I—I 2 COATING ❑ 3 VINYL WRAP ❑ t FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION 5 CATHODIC PROTECTION �❑ 9T NONE ❑95 UNKNOWN 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAWMENT INSTALLED(YEAR) OVERFILL PREVENTION ECUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND.BOTH IF APPUCASLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE 'WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U A FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 8 CONCRETE A U 7 STEELWI COATING A U 8 100% METHANOL CCMPATIBLE WIFRP <br /> PROTECTION A U 9 GALVANQEO STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> 0. LEAK DETECTION ❑ I AUTOMATIC UNE LEAK DETECTOR ❑ 2 UNE TIGHTNESS TESTING ❑ )'MONRORING ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ d AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ a TANK TESTING I❑ 7 INTERSTITIAL MONITORING a 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MOIOAYNR) I 2.ESTIMATED OUANTRYOF 3.WAS TANK FILLED WITH YES ^-I NO I` <br /> SUBSTANCE REMAINING GALLONS IN MATERIAL? L� <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE ��/ <br /> IPPINTE9 A SIGNATURE( ✓Y7 <br /> LOCAL AGENCY USE ONLY THE STATE LD.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY x JURISDICTION x FACILITY x TANK x <br /> STATE I.D.;# 1--i"T = ! <br /> PERMIT NUMBER PERMIT APPROVED BY10ATE PERMIT EXPIRATION OATS <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FILETHIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGETANK REGULATK)N8 <br /> FORM B (1291) WP06it8.T6 <br /> /� <br />
The URL can be used to link to this page
Your browser does not support the video tag.