My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1986 - 1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2358
>
2300 - Underground Storage Tank Program
>
PR0231756
>
BILLING 1986 - 1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:14:33 AM
Creation date
11/7/2018 8:57:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1986 - 1999
RECORD_ID
PR0231756
PE
2361
FACILITY_ID
FA0006343
FACILITY_NAME
ALPHA FAST GAS*
STREET_NUMBER
2358
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14118221
CURRENT_STATUS
01
SITE_LOCATION
2358 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\2358\PR0231756\BILLING 1986 - 1999.PDF
QuestysFileName
BILLING 1986 - 1999
QuestysRecordDate
8/6/2018 11:42:10 PM
QuestysRecordID
3955989
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> 1�1 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOe -QU <br /> ONE ITEM 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ '6 TEMPORARY TANK CLOSURE ❑ 86 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: �SC ^7-'_ <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TAN�D. <br /> B. MANUFACTURED BY:C. DATE INSTALLAYIYEAR} D. TANK CAPACITY IN GALLONS: <br /> II TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> ❑ 1a REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> A. 9 MOTOR VEHICLE FUEL ❑ 4 OIL B>:rl <br /> C." 1b PREMIUM UNLEADED ❑ 4 GASAHOL 7 METHANOL <br /> 2 PETROLEUM ❑ 80 EMPTYPRODUCT <br /> 1c MIDGRADE UNLEADED ❑ S JET FUEL ❑ B M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S. <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> F71 DOUBLE WALL a 3 SINGLE WALL WITH EXTERIOR LINER Li5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> A. TYPE OF <br /> SYSTEM ❑ 2 SINGLE WALL 4 SINGLE WALL IN k VAULT EJ 99 OTHER <br /> 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W!FIBERGLASS REINFORCED PLASTIC <br /> B. TANK <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM B 100% METHANOL COMPATIBLE WlFRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY UNING [j4 PHENCLIC LINING <br /> C.INTERIOR <br /> LINING OR 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES, NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP 2 COATING [-] 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION ( <br /> 95 UNKNOWN ❑ 99 OTHER <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE❑ <br /> SPILL CONTAINM NT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT 1NSTALLED(YEAR} <br /> E.SPILL AND OVERFILL,Etc. DROP TUBE YES NO STRIKER PLATE VES NO DISPENSER CONTAINMENT YES NO <br /> 1V.PIPING INFORMATION CIRCLE A IF ABOVEGROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION f.U2 <br /> 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLE7A <br /> DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A,2)4 FIBERGLASS PIPE <br /> A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE WIFRP <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> 1 MECHANICAL LINE LEAK 2 HE TIGHTNESS 3 CONTINUOUS INTERSTITIAL 4 ELECTRONIC LINE 5 AUTOMATIC PUMP 99 OTHER <br /> M LEAK DETECTION ❑ DETECTOR TESTING MONITORING LEAK CETECTOR SHUTDOWN ❑ <br /> V.TANK LEAK DETECTION <br /> Y�l <br /> VISUAL CHECK ❑ 2 MANUALRECONCINVENTTIONORY ❑ 3 VA,DOMONIBRING ❑ 4 GAUGING AUTOMATIC TANK ❑ 5 MONTORINGOUND TER ❑ 5 TESTINGANNUAL <br /> CONTINUOUS INTERSTITIAL ❑ B SIR ❑ 9 WEEKLY <br /> GAUGINGANUAL ❑ 10 MO TESTING TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> MONTORING <br /> `111.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED{MOIDAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO El REMAINING GALLONS INERT MATERIAL. <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> DATE <br /> TANK OWNER'S NAME <br /> (PRINTED 6 SIGNATURE) ' <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW �, J 5 " <br /> COUNTY# JURISDICTION# FACILITY# 3 TANK# <br /> STATE 04 = UV5T�l � <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PL FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTINERGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) q� j 9wq <br />
The URL can be used to link to this page
Your browser does not support the video tag.