My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1993 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2358
>
2300 - Underground Storage Tank Program
>
PR0231756
>
BILLING 1993 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2023 12:52:46 PM
Creation date
11/7/2018 9:01:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1993 - 2012
RECORD_ID
PR0231756
PE
2361
FACILITY_ID
FA0006343
FACILITY_NAME
ALPHA FAST GAS*
STREET_NUMBER
2358
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14118221
CURRENT_STATUS
01
SITE_LOCATION
2358 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\2358\PR0231756\BILLING 1993 - 2012.PDF
QuestysFileName
BILLING 1993 - 2012
QuestysRecordDate
8/7/2018 7:50:20 PM
QuestysRecordID
3956920
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING PLAN -- PAGE 2 <br /> VI.DISPENSER MONITORING <br /> MONITORING OF AREAS BENEATH DISP€`:SER(S)IS PERFORMED USING THE FOLLOWING METHODS)(Check all that apple) M"' <br /> Q 1.CONTINUOUS MONITORING OF L'\DER DISPENSER CONTAINMENT(LIDC) <br /> PANEL MANUFACTURER' CARL6r+_ M51 MODEL;r: mi, <br /> LEAK SENSOR MANUFACTURER `'ti'. MODL•I."(Sy M54. <br /> WILL DETECTION OFA LEAK IN THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? a.YESRro.NO n15z <br /> WILL A UDC LEAK AI_1.RN1 TRIGGER AUTOMATIC PUMP SHUTDOWN' ,ji�a.YES ❑ b.NO <br /> "'ILL FAILUREIDISCONNECTIONOF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUNIP SHUTDOWN' -Ta.YES ❑ b NO 1157 <br /> 2 MECHANICAL CONTINUOS MIONITO 1NG Ie- FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br /> MANUFACTURER. R " " MODEL#(S): WC <br /> ❑ 3.VISUAL MONITORING DONE A07A.DAILY [ b.WEFKLY NMI <br /> i ❑ 4.NO DISPENSERS <br /> Q 99,OTHER(Specity) MGk <br /> VII. ENHANCED LEAK DETECTION <br /> 1.W7-14A V E BEEN NOTIFIED BY THE STATE'%�ATE.R RESOURCES CONTROL BOARD THAT WE MUST PER ENHANCED LEAK M11t6 <br /> DETECTION(FLD1 FOR THE UST(S)COVERED 8) THIS PLAN,PEP,23 CCR 32644 1.ELD 15 PERFORMED EVERY 36 NIONTHS AS REQUIRED <br /> N7III. TRAINING <br /> REFERENCE DOCUMENTS MAINTAINED Al-FACILITY(Check all that apply) Attu, <br /> 1. THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> ? OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) <br /> 3_ THE FACILITY'S BEST NIAN'.AGEMENT PRACTICES(Required as of January 1,20055 <br /> 4. CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. ❑ CALIFORNTA LINDERGROUND STORAGE TANK LAW <br /> fi_ Q STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION "HANDBOOK FOR TANK OWNERS - MAN[iAL AND <br /> STATISTICAL INVENTOR)'RECONCILIATION" <br /> 7. C SWRCB PUBLICATION `WEEKLY MANUAL TANK GAUGING FUR SMALL UNDERGROUND STORAGE TANK$" <br /> 99. t_i OTHER(Spec ifj)- MMI <br /> Personnel will}UST monitoring respensi a Rtes arz ami lar 111th all o t he above documents re evan(to i teirto n:l2s ana car.access t ase docurnerkis 11 cn needed. <br /> By Januar% I._'1005,chis facility will have a"D .sated LIST Operator"%,.Ito has passed the Caliromia UST Sviem Operator E.wam administered by the intemariana <br /> Code Council(ICCI B" RA I,20W,and annuall} thereafter,th- `Designated UST Op;raior"will train merlin empiovees In the proper operation and maintenance <br /> of the UST Systeme.Tl-,is t-:fining t+rill include,b:it is not limited tu,the fol.Ming. <br /> i Operation ofthe UST s+siems in a manner consistent with the facilin's best malta-Eeln-11t Practices. <br /> > <br /> The facility employcrc's role with regard w the leak detection equiPrnent, <br /> i The facilitN'employee's role with regard tc spills and 01'etf lls. <br /> Whom to contact for emergencies and leak detection alarms. <br /> For tacilin employees hired on or after Jule I,2DOs,the initial training N%ill be eonaucted within 30 dais of the date of hires <br /> IX. COMNMNTS/ADDITIONA.L INFORMATION <br /> Please use this Section(O include.ani"aJdwona]LIST sYstum nimiaor na•realed I fl at On fe.q,�ddlt"anal Inf0t7]:liLfl r C�1:1 'C�`, 10(y� al amen[' ��~ <br /> ��� <br /> AT q /s <br /> X. PERSONNEL RESPONSIBILITIES <br /> A5 OF .ANUARY 1. 2005. THE "DESIGNATED LST OPERATOR- IDENTIFIED IN SECTION 111 OF THE CURRENT UST OPERATING PFRMiT <br /> APPLICATION - FACILITY FORh1 WILL HAVE UI-1-1.LLATE AL'THuR1TY FOR PERFORMING T14E MONITORING ACTIVITIES AND .'4MAINTAINING , <br /> LEAK DETECTION EOUIPMEN T COVERED BY'('NIS PLAN TITLE-;3 CCR ; 2715(ci.AND 1>,'11,.1-PERFOPM AND DOCUMENT MINIMUM kIONTHLY I <br /> VISUAL INSPECTIONS OF THEFACILITY'S LIST SYSTEMS iN ACCORDANCE W< TH TITLE 23 CCR 2715(cI. <br /> XI. ONVNER/OPERATOR SIGNATURE <br /> CERTIFICATION: I certify that the information pr•o d herein is true and accurate to the best of in,, knowledge. <br /> OWNER)OPERPC, [,QSIGNAT 'REERS \T tic; DATE rtt,l <br /> `•I�r ��y,�v�l,�-� liner also <br /> I Orre atar <br /> O1hNEI:c)PERATOP.NAME itarinC st ONVNER�OPERATOR TITLE. 1t't <br /> (Agog 7 t.rsa On1.1 i This plan ha; �ezn rev:e',tcd and �pproved Ej Appmo ed With CondinorsDilaPPr <br /> oved <br /> Local Agency Signature Date <br /> ComirenGlSp:cial Cnr.dinons'. <br /> I — <br /> hwf%re-d(W24)04)-314 <br />
The URL can be used to link to this page
Your browser does not support the video tag.