My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1986-1997
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
BILLING 1986-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 1:29:46 PM
Creation date
11/7/2018 9:21:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1986-1997
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\4407\PR0231761\BILLING 1986-1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA ..... <br /> ` <br /> STATE WATER RESOURCES CONTROL BOARD =� ' <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT <br /> ONE ITEM ❑ 2 INTERIM PERMIT 5 CHANGE OF INFORMATION ] PERMANENTLY CLOSE SIT <br /> ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE <br /> 6 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: cy l O 7 <br /> c, <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A, OWNER'S TANK I.D.X 03 B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) <br /> 7 D. TANK CAPACITY IN GALLONS: <br /> ILTANKCONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A. ;IF((A.1) <br /> 1 MOT3 DIESEL <br /> OR VEHICLE FUEL ❑ 4 OIL B. ❑ la REGULAR o <br /> 2 PETROLEUM 60 EMPTY 1 PgODUC7 C -�/ EADED ❑ y GASAHOL ❑ 6 AVIATIONGAS <br /> 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE 1b PREMIUM ❑ 5 JET FUEL ] METHANOL <br /> UNLEADED2 LEADED 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br /> C.A.S.x <br /> III. TANK CONSTRUCTION MARKONEITEMONLYINBOXESq,B,AND C.AND ALL THAT APPLIES IN BOX DANOE <br /> f <br /> F ❑ ,BLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER <br /> M O' ❑ ❑ 95 UNKNOWN <br /> 2 SINGLE WALL 4 SEDONOARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> AL ❑ 5 CONCRETE ❑ e POLYVINYL CHLORIDE ❑ 7 ALUMINUM <br /> ank) ❑ g BRONZE ❑ 6 100% METHANOL COMPATIBLE W/FRP <br /> ❑ 10 GALVANIZED STEEL �9s UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING 3 EPDXY LINING <br /> C.INTERIOR ❑ ❑ 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑ 6 UNLINED <br /> 5 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO_ <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP <br /> PROTECTION ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 5 UNKNOWN <br /> ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) <br /> OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVE GR NO OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A PRESSURE <br /> A U 3 GRAVITY p U 99 OTHER <br /> B. CONSTRUCTION A SINGLE WALL A U 2 DOUBLE WALL <br /> A U 3 LINED TRENCH p U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL <br /> CORROSION A U A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> 5 ALUMINUM A U 6 CONCRETE <br /> PROTECTION U ] ST L W/COATING A U 6 100% METHANOL COMPATIBLE W/FRP <br /> A U 9 VANIZED STEEL p D 10 CATHODIC PRO ECTION 5 UNKNOWN <br /> D. LEAK DETECTION 1 AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING A U 99 OTHER <br /> V.TANK LEAK DETECTION MONRORIuc ❑99 OTHER <br /> ❑ 1 VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> ❑ 6 TANK TESTING ❑ ] INTERSTITIAL MONITORING91 NONE <br /> ❑ ❑ 95 UNKNOWN 09 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED OUANTITV OF <br /> SUBSTANCE REMAINING 3.WAS TANK FILLED WITH ❑ <br /> GALLONS INERT MATERIAL? YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MV KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY STATE I.D.# r TANK# <br /> PERM(TNUMBER p Z 3 I 6 I C <br /> PERMIT APPROVED BV/DATE PERMIT EXPIRATION DATE _ <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORMA,UNLESS A CURRENT FORM A HAS BEEN�LED.y <br /> FORM B (12-91) <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> • � �� FOR11l16-q6 <br /> l <br />
The URL can be used to link to this page
Your browser does not support the video tag.