Laserfiche WebLink
r <br /> IFIED PROGRAM CONSOLIDATED FOR Z�Zl�� TANK: TA0508322 <br /> l PR#: PR0231761 <br /> UNDERGROUND STORAGE TANKS -TANK PAG EACH: FA0002347 <br /> (two pages per tank) <br /> Pagc 6 of7 <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ S CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Chmkmlyiimanly) r - ❑ 7 PERMANENTLY CLOSED ON SITE <br /> n mvlowl mannlY) <br /> El3RENEWAL PERMIT ❑ &TANK REMOVED 430 <br /> BUSINESS NAME(Samc as FACILITY NAME or DBA-Poing Bmmm Aa) FACILITY ID: PRN <br /> : 1 <br /> ERNIES GENERAL STORE 3 FA0002347 PRO231761 <br /> LOCA TION WITHIN SITE(opnmaq 4407 E WATERLOO RD,STOCKTON 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan With the location of the UST system including buildings and landmarks shall be subndtted to the local agency.) <br /> TANK ID# Tank#: 6 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK E]Yes E]No 434 <br /> ID <br /> TA0508322 FLUCONTAINMENT INC H^Ym•.msq'Ietcmepageformehe mpament. <br /> DATE EVSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 12/29/1998 5,000 <br /> ADDITIONAL DESCRIPTION(Fmlaml meomy) 439 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 44o <br /> ® I.MOTOR VEHICLE FUEL ❑ la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> ofmw1dmm,I.Pmo.Type) ® Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic.MIDGRADE UNLEADED ❑ 4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME rymn Haus4mn Mmai.Is Iwmlmy page) 441 CASH(am,Haadmn M.tmiab Immmy page) 442 <br /> ❑ 4.HAZARDOUS WASTE <br /> (Includm osdao <br /> ❑ 95.UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (L'heckmmitmm0y) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ®2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-Primary lank ❑ 1.BARE STEEL ® FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check ane iIm may) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD WNTEERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) [199.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Chink me imn mly) ❑ 2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/10056 METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ L RUBBER LINED ❑ I.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN a6 DATE INSTALLED a47 <br /> OR COATING <br /> (Check one ima mJ6 El2ALKYD LINING ❑4PHENOLIC LINING El6UNLINED E] 99.OTHER <br /> (Fm laml we only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ® 3 FIBERGLASS UNFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED u9 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑ 4IMPRESSED CURRENT ❑ 99 OTHER <br /> (L'hect meitmanN) ❑2SACRIFICIAL ANODE (Fm local mcmy) <br /> SPILL AND OVERFILL YEAR INSTALLE45D TYPE(ladmeomy) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check <br /> an dm apply) ❑ 1 SPILL CONTAINMENT ❑ 1ALARM [-13 FILL TUBE SHUT OFF VAL` <br /> ❑ 2 DROP TUBE ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A d criptim ofdammimdngPMPam 5WIleaubmind w she lam]agcmy.) <br /> IF SINGLE WALL TANK(Checkall ma ply) 4$3 IF DOUBLE WALL TANK ORTANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check me nm only) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑7 GROUNDWATER ❑2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ STANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAININ< 1ITH INERT MATERIAL? 457 <br /> 12/29/1998 )0 gallons ❑Yes ❑No <br /> UPCF(12/99 revised) 40 <br /> 0 <br />