Laserfiche WebLink
EHD 23-01 Rev. 0922/16 <br />FA0002347 PRO231761 SCO01 01222018 <br />Page 1 of 6 Underground Storage Tank Program OIR <br />9171 9690 0935 0152 1704 67 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ERNIES GENERAL STORE <br />Facility Phone: <br />(209) 931-2850 <br />Date: <br />January 22, 2018 <br />Facility Address: <br />4407 E WATERLOO RD, STOCKTON, CA 95215 <br />CERS ID: <br />10180913 <br />Inspection Contact:Title: <br />Ernest Giannecchini <br />Owner <br />Phone; <br />(209) 931-2850 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For:Consent <br />0 Inspection © Photos O Samples <br />Given By: <br />Ernest Giannecchini, Owner <br />Service Technician Onsite: <br />David Winkler <br />Exp. Date: <br />03/01/2018 <br />Designated Operator. <br />Zane Nimmo <br />Exp. Date: <br />08/26/2018 <br />Service Technician Manufacturers Training: <br />TT, 03/31/20; VMI, 11/15/19; VR, 02/03/18 <br />CCR= California Code of Regulations HSC = Health and Safety Cade CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />File Review <br />101 <br />HSC 25284 <br />Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees <br />o V <br />o R o COS <br />102 <br />HSC 25284(a)(3)(A)/(B) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V <br />in R o COS <br />103 <br />HSC 25292.2, 25299.30 <br />Current financial responsibility documents not submitted <br />. V <br />. R . COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />o V <br />o R o COS <br />105 <br />CCR 2632(d)(1), <br />2634(d <br />Failed to have an approved UST monitoring plan <br />o V <br />n R c COS <br />106 <br />CCR 2632(d)(2), <br />2634(e) <br />Failed to have an approved UST response plan <br />o V <br />o R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />. V <br />o R . COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />o V <br />o R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />in V <br />in R in COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />o V <br />o R o COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />o V <br />D R o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />D V <br />o R o COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />o V <br />D R D COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />o V <br />D R o COS <br />115 <br />CCR 2715(a) <br />Failed to submit to EHD notification of designated operator identification or change w/in 30 days <br />o V <br />o R o COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess wren ICC certification <br />in V <br />D R in COS <br />117 <br />CCR 2663(h) <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />o V <br />o R o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />o V <br />o R o COS <br />119 <br />HSC 25299(a)(8), <br />25299(b)(7) <br />Documents were falsified or misrepresented <br />o V <br />o R D COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modificatlon <br />o V <br />o R o COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />o V <br />D R D COS <br />122 <br />CCR 26310) <br />Failure to submit and maintain UST system component statement of wmpatibility for substance stored <br />n V <br />o R in COS <br />On Site Records <br />201 <br />CCR 2712(b) <br />Failure to maintain monitoring, maintenance, and follow up action records <br />i V <br />o R o COS <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />o V <br />o R o COS <br />EHD 23-01 Rev. 0922/16 <br />FA0002347 PRO231761 SCO01 01222018 <br />Page 1 of 6 Underground Storage Tank Program OIR <br />9171 9690 0935 0152 1704 67 <br />