My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 1:46:26 PM
Creation date
11/7/2018 9:23:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WATERLOO\4407\PR0231761\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sioov.orc/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ERNIES GENERAL STORE <br />Facility Address: <br />4407 E WATERLOO RD, STOCKTON <br />Date: <br />January 22, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The approximate location of the underground storage <br />tank piping is missing from the site plan. A site plan must be submitted identifying the locations where monitoring <br />will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.ralepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This was corrected on site. <br />This is a minor violation. <br />307 <br />CCR 2631(g), 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br />The 91-diesel split-tank annular sensor activated an audible and visual alarm when tested, however the service <br />technician was unable to place the annular sensor back into its proper position due to the string attached to the <br />sensor braking, therefore, the 91-diesel split tank is not monitored. The interstitial space shall be monitored with a <br />monitoring system connected to an audible and visual alarm system. Immediately contact a property licensed, <br />trained, and certified contractor to replace the failed component with a functional component (LG 113-x listed, if <br />applicable) under permit and inspection of the EHD within one business day. <br />This is a Class II violation. <br />309 <br />CCR 2636(f)(1) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product. <br />A float and chain in under dispenser containment (UDC) 7/8 and the float and chain in UDC Diesel #2 failed to stop <br />the flow of product at the dispenser when tested. The service technician removed the dirt around the float and <br />chains, re-tested the float and chains, and both passed. All monitoring equipment shall be maintained to activate an <br />audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br />This was corrected on site. <br />This is a minor violation. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br />3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A "UST <br />Retrofit Verification with Inspector Already Onsite" form has been completed and provided to the operator and <br />contractor. <br />This was corrected on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 2/22/2018. <br />FA0002347 PRO231761 SC001 01/22/2018 <br />EHD 23-01 Rev. 09f22116 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.