San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sioov.orc/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ERNIES GENERAL STORE <br />Facility Address: <br />4407 E WATERLOO RD, STOCKTON <br />Date: <br />January 22, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The approximate location of the underground storage <br />tank piping is missing from the site plan. A site plan must be submitted identifying the locations where monitoring <br />will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.ralepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This was corrected on site. <br />This is a minor violation. <br />307 <br />CCR 2631(g), 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br />The 91-diesel split-tank annular sensor activated an audible and visual alarm when tested, however the service <br />technician was unable to place the annular sensor back into its proper position due to the string attached to the <br />sensor braking, therefore, the 91-diesel split tank is not monitored. The interstitial space shall be monitored with a <br />monitoring system connected to an audible and visual alarm system. Immediately contact a property licensed, <br />trained, and certified contractor to replace the failed component with a functional component (LG 113-x listed, if <br />applicable) under permit and inspection of the EHD within one business day. <br />This is a Class II violation. <br />309 <br />CCR 2636(f)(1) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product. <br />A float and chain in under dispenser containment (UDC) 7/8 and the float and chain in UDC Diesel #2 failed to stop <br />the flow of product at the dispenser when tested. The service technician removed the dirt around the float and <br />chains, re-tested the float and chains, and both passed. All monitoring equipment shall be maintained to activate an <br />audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br />This was corrected on site. <br />This is a minor violation. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br />3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A "UST <br />Retrofit Verification with Inspector Already Onsite" form has been completed and provided to the operator and <br />contractor. <br />This was corrected on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 2/22/2018. <br />FA0002347 PRO231761 SC001 01/22/2018 <br />EHD 23-01 Rev. 09f22116 Page 4 of 5 Underground Storage Tank Program OIR <br />