Laserfiche WebLink
2� <br /> PETROLEUM PROJECT DESCRIPTION p <br /> REMOVE EXISTING AND INSTALL NEW PIPING, ISLANDS, DISPENSERS, AS SHOWN. �° P <br /> GASOLINE DISPENSERS ARE TO BE FIXED BLENDER, MULTI-PRODUCT. <br /> m STORED PRODUCTS LIMITED TO HIGH 4 LOW OCTANE UNLEADED GASOLINE 4 DIESEL. Q Q <br /> 23 KEYNOTES, SCOPE Q O p @ J- <br /> O I 22 0. REMOVE EXISTING DISPENSERS, ISLAND, DRIVE SLABS, PIPING, UNDERGROUND <br /> STORAGE TANKS (11 o 5,000 , 1 a 10,000 , 1 m 12,000. APPROX. LOCATION AS SHOWN.) cj <br /> 1. 3 - NEW 2"0 TANK VENT RISERS. INSTALL NEW SWING JOINTS AT BASE AND <br /> CONNECT TO NEW VENT LINES. �A Q °� <br /> . - - „ 2. 2"0 FIBERGLASS TANK VENT LINES SLOPED BACK TO EACH TANK AT IIB" PER L� <br /> ° - .- „ -- „ FOOT, MIN. 0 <br /> ° P R O P O 5 E D f? A RK I ',N G 1 0 M N I M U M' ) I I 3. GILBARCO 3.1 MPD FIXED BLENDER DISPENSERS ON BRAVO BOX Q <br /> o CONTAINMENT/SHEAR VALVE SYSTEMS. TYPICAL OF 2. <br /> 8 4. GILBARCO 3+0 MPD FIXED BLENDER DISPENSERS ON BRAVO BOX <br /> o it CONTAINMENT/SHEAR VALVE SYSTEMS. TYPICAL OF 2. <br /> „ <br /> „ <br /> ° 5. 3`0 FIBERGLASS PHASE 11 VAPOR RECOVERY PIPING FROM DISPENSERS TO <br /> lU - u <br /> d _ _� _ TANKS. SLOPE I/8 F007 MINIMUM BACK 70 TANK (2"0 OK TO SINGLE MPD.) <br /> 0 U ° - -O 11 O -J'I' <br /> 0 0. 2I w I I U) 1W 1 6. 2 0 PRODUCT PIPE W/ 3 0 SECONDARY CONTAINMENT, TYPICAL ALL PRODUCTS. <br /> ° x I % w I 13 SLOPE BACK TO TANK$ At 1/B" PER FOOT MIN. ORLANDO' S <br /> „ �� Z i„ O01 j� AC PAVING, NEW T. NEW UNDERGROUND FUEL STORAGE TANKS. I-12,000 GALLON UNLD. REG., 5G>II E. WATERLOO RD. <br /> m W/IN NEW FENCING 1-12,000 SPLIT 6,000 UNLD. SUPER AND 6,000 DIESEL. STOCKTON, CA 95215 <br /> =0 1209) 931-2942 <br /> 8. TANK ANNULAR SPACE W/ TANK PROBE AND W.T. MANWAY. TYP. OF 2. APN 087-100-52 <br /> - Axl 9. TANK FILL W/ 5 GALLON FILL CONTAINMENT. TYPICAL OF 3. <br /> ----------------- -------------- �� U <br /> _ -- <br /> _ 20 -4 10. PHASE I (DRYBREAK) VAPOR RECOVERY, W/ 12" MIN. MANHOLE. TYP. OF 2. s <br /> ?T he - Il. MAGNETOSTRICTIVE TANK GAUGE WAN W.T. MANWAY. TYPICAL OF 3. [q <br /> I�F L__- J L �J - - - --- ° <br /> IQJ . _ __ o - o ° 0 0 12. SUBMERSIBLE TURBINE PUMP (STP) WAN 42"0 F.R.P. SUMP W/ FLOAT SWITCH SUMP <br /> ( - r -- T PROBE (AUTO STP SHUTDOWN ON ALARM), LIE) AND 36" MANWAY. TYP. OF 3. ALTON <br /> - - - _ 3. 8 THICK CONCRETE TANK SLAB W/ 04 REBAR AT IS O.G. BOTH WAYS. <br /> NGINEERING, INC. <br /> BL . �L t 14. BACKFILL TRENCHES WITH PEA GRAVEL TO LEVEL REQUIRED <br /> I -I FOR NEW SLURRY COVERAND PAVING BASE, PROVIDE SLURRY : P.O. BOX 1025 <br /> 12' 32' I 12' CONCRETE 4" THICK (MIN.) OVER PEA GRAVEL. BACKFILL EXISTING <br /> EXISTING - r- AG PAVING, ETR 543 RISKE LANE <br /> f, ( TANK HOLE W/SPOILS FROM NEW EXCAVATION. ENGINEER FOR 6" LIFTS, MOISTURE WEST SACRAMENTO, CA 95691 <br /> MARKET I - I MINIMUM OF 9591 RELATIVE COMPACTION. (916) 312-1868 <br /> _ I OVER 6 AGGREGATE BASE. FAX 313-1112 <br /> 3991 SQ. FT. 15. NEW (2" <br /> NCK CONCRETE DRIVE SLAB W/, 04 REBAR AT 24" O.C. BOTH WAYS, <br /> 40' S6 <br /> " THEE DRAWW38 AND SPECIFICATION$,AS <br /> _. NSTRLMTS OF SERVICE,REMAN THE <br /> 2 0 PROPERTY OF WALTON D4NEERWX NC. <br /> { O 16: MONITOR CONTROLS AND ALARM, W/ VISUAL 4 AUDIBLE ACCESSIBILITY. AND SHALL NOT BE USED FOR ANY PWWO66 <br /> _ OTHER THAN TH08E FOR WCH THEY HAVE <br /> MEN�� I I 11. NEW E.S.O. W/ VISIBLE SIGN, SEE GENERAL NOTES, ALLNOT MREPPROCtrCEOR �CDOPPIEo TRACED <br /> 1� - - OTHCUT THE E%PRE68 MtTEN C40NUNT OF <br /> MTON EWiNEERM, NC. <br /> 10. EXIST. AIR/WATER (UNIT TO BE RELOCATED, BY OTHERS, CONFIRM LOCATION. <br /> qqr t I Br COPYRIGHT © 1996 <br /> 19. PATCH A.G. PAVING AS REQ'D. MATCH EXISTING PAVING SECTIONS. <br /> \ i TYP 20. NEW CANOPY, 55' x 45', BY OTHERS. <br /> 'DRAWN BY 7G <br /> - I L _ .r __ __ - ----- 21. EXIST. PROPANE DISP. SYSTEM TO BE RELOCATED, BY OTHERS, CONFIRM LOC- CHKD' BY MEL/MEW <br /> - <br /> 22. RELOCATE/ADD NEW FENCING, BY OTHERS, CONFIRM LOCATION. DATE 30 AUG 96 <br /> 23. ABANDON EXISTING 4 INSTALL NEW LEACH FIELD. PERMIT 4 WORK BY OTHERS. SALE 11,210' <br /> JOB NO. 26610 <br /> EXIT I N G PARI< I Cz; (10) II e� l �I 7HI,�< s m ZSt � <br /> nz GENERAL NOTES <br /> p I: AG PAVING, ETR i <br /> SIGN, PHONE, µ. I REVISIONS <br /> AC PAVING, ETR BOLLARDS (E) PROVIDE AT LEAST ONE PORTABLE FIRE EXTINGUISHER W/ A MINIMUM RATING <br /> S 52' 04' W 329.83' fE - - - - / OF 2-A,20-B:C WITHIN SEVENTY-FIVE (15) FEET OF ANY PUMP, DISPENSER, DATE REV DESCRIPTION B <br /> _ - - - - - - - - - - - -- - - OR FILL-PIPE OPENING, THIS EXTINGUISHER TO BE AFFIXED TO A LOCATION <br /> - EXISTING ON A MOUNTING BRACKET OR IN A FIRE EXTINGUISHER CABINET. (UFC 19.905) <br /> EXISTING DRIVEWAY SWALE, E.T.R. DRIVEWAY A CLEARLY LABELED, MANUALLY OPERATED PUMP MASTER SWITCH SHALL <br /> BE PROVIDED IN AN APPROVED LOCATION W/IN 15 FEET, BUT NOT NEARER <br /> THAN 25 FEET TO, ANY DISPENSER WHERE SUCH MASTER SWITCH IS NOT <br /> VISIBLE FROM ALL DISPENSERS, THE LOCATION THEREOF SHALL BE INDICATED <br /> BY APPROVED SIGNS. SIGNS IDENTIFYING THE PUMP MASTER SWITCH SHALL <br /> BE LABELED "EMERGENCY FUEL SHUTDOWN DEVICE". THE MASTER SWITCH ON <br /> WATERLOO R O A D ALL INDIVIDUAL PUMP CIRCUIT SWITCHES SHALL BE SET IN THE "OFF" POSITION <br /> BEFORE CLOSING THE STATION FOR BUSINESS AT ANY TIME. (UFC 5201.53) <br /> UNFINISHED ABOVEGROUND METALS SHALL BE CLEANED, PRIMED, AND PAINTED .01 <br /> WITH SUITABLE MATERIALS. COORDINATE COLORS WITH OWNER. <br /> P E T R O L E U M S I T E P L A N ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND TESTED PER SHEET TITLE <br /> -- ---- - -- --- - ----- --- MANUFACTURER'S INSTRUCTIONS, APPLICABLE CODES AND STANDARDS, <br /> SCALE: 1"-10' (USE GRAPHIC SCALE FOR REDUCED PLOTS) THE PLANS AND SPECIFICATIONS, AND LOCAL AGENCY REQUIREMENTS. <br /> PETROLEUM <br /> ®� - GOVERNING CODES PETROLEUM SHEET INDEX SITE PLAN <br /> 0 5 10 20 30 40 50 GOVERNING CODES AND STANDARDS INCLUDE, BUT SHALL NOT BE PI=T-0 EXISTING SITE PLAN, VICINITY MAP <br /> LIMITED TO, THE STANDARDS OF THE FOLLOWING: PET- I PETROLEUM SITE PLAN <br /> PARKING UNIFORM FIRE CODE (UFC) KEYNOTES, SCOPE <br /> UNIFORM BUILDING CODE (UBC) PET-2 GASOLINE TANK SECTION, SLAB <br /> REQ'D: 4/1000 SF. STORE NATIONAL ELECTRIC CODE (NEC) <br /> 2 PER 3 EMPLOYEES NATIONAL FIRE PROTECTION AGENCY (NFPA) PET-3 SPLIT TANK SECTION ® .g <br /> REQUIRED - IS SPACES CALIFORNIA UNDERGROUND TANK STORAGE REGULATIONS PET-4 PETROLEUM DETAILS PET ®® <br /> PROVIDED - 20, MINIMUM LOCAL ORDINANCES PET-5 PETROLEUM NOTES, SCOPE, CLOSURE OF <br /> (o SHEETS <br />