Laserfiche WebLink
I T T S Integrity Tank Testing Spste <br /> �.:O <br /> JUN 21 19ap) <br /> ENF1ERIv11T/SERV CES HEALTH <br /> TEST DATA AND <br /> TEST RESULTS <br /> November 19 , 1987 <br /> Don ' s Distributing Co. <br /> 1320 West Weber Ave. <br /> Stockton , California <br /> Dear Mr. Keller , <br /> Followlag is a summar-v of. the precision testing we recently <br /> conducted oil your underground storage tank(s) . <br /> Attached are copies of the test worksheets and graphs grnr- <br /> rated for your submittal to the appropriate governmental agency . <br /> A tank vystem is considered tight: , according to the current <br /> rules , if the gain is less than .02 or lila loss is less than . NS <br /> gaticns prr one hour of testing. If the results are beyond these <br /> pnr�1netecs , you should consider taking some remedial action . <br /> TANK #/ TANK PRODUCT TEST WITHIN TIG11'1' <br /> LOVAT10N CAPACITY CONTAINED RESULTS TANK PARAHETE..RS <br /> North Tank <br /> Test One 3 ,000 Gasoline -. 1735 No <br /> During this test I kept noticing that the ground around the fill & <br /> Phase One Vapor was getting wet.. Eventhough I had dried it prior to <br /> starting the test. I attempted to tighten both., lines , but the small <br /> opening would not allow proper leverage. Please note the sketch & the <br /> comments on the reverse side of the worksheets. <br /> Test Two 3,000 Gasoline -. 011376 Yes <br /> 1-ase. contact uc ii you u--ed additional assistatt^_v or <br /> Cn�•.�:.riut ire.. <br /> Sinccrel.y , <br /> W N <br /> Cart le ester <br /> 800 262 TEST 166 Fr mk West Circle Stockton, CA 95206 (209) 466-8036 <br />