Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0527326
PE
2361
FACILITY_ID
FA0018501
FACILITY_NAME
SJC CAPITAL PROJECTS
STREET_NUMBER
304
Direction
E
STREET_NAME
WEBER
STREET_TYPE
AVE
City
STOCKTON
Zip
95202
APN
14916002
CURRENT_STATUS
02
SITE_LOCATION
304 E WEBER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEBER\304\PR0527326\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/12/2017 9:36:27 PM
QuestysRecordID
3677998
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM �r-� <br /> TANKS a 7 <br /> UNDERGROUND STORAGE TANKS- TANK PAGE 2 <br /> P e of <br /> VL PIPING CONSTRUCTION(cnmt vt uw 1) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑L PRESSURE [12.SUCTION C73.GRAVITY 458. ❑1.PRESSURE [12.SUCTION .GRAVITY 459. <br /> CONSTRUCTION/ Q.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460. .SINGLE WALL <br /> MANUFACTURER [3 95.UNKNOWN 462. <br /> [:12.DOUBLE WALL ❑95.UNKNOWN [12.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER 461. MANUFACTURER 463. <br /> �I.BARE STEEL ❑6.FRP COMPATIBLE W/100%METHANOL .BARE STEEL A, rr ❑6.FRP COMPATIBLE W/100%METHANOL <br /> .STAINLESS STEEL ❑7.GALVANIZED STEEL / 2.STAINLESS STEEL I A ❑7.GALVANIZED STEEL <br /> ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑95.UNKNOWN [13.PLASTIC COMPATIBLE W/CONTENTS ❑S.FLEXIBLE(HDPE) ❑99.OTHER <br /> ❑4.FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑99.OTHER [14.FIBERGLASS <br /> ❑9.CATHODIC PROTECTION <br /> ❑S.STEEL W/COATING ❑9.CATHODIC PROTECTION 464. ❑5.STEEL W/COATING [195.UNKNOWN 465. <br /> VII.PIPING LEAK DETECTION(GT«t 91 that A of0w mo�om� 9hatlhmbmntaemroebol .) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466. SINGLE WALL PIPING 467, <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check a3 that apply): <br /> ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> SHUT-OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION <br /> +AUDIBLE AND VISUAL ALARMS. +AUDIBLE AND VISUAL ALARMS. <br /> ❑2. MONTHLY 0.2 GPH TEST [32. MONTHLY 0.2 GPH TEST <br /> [13. ANNUAL INTEGRITY TEST(0.1 GPH) [13. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [14. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING <br /> INTEGRITY TEST(0.1 GPH) 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): [16. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> ❑7. SELF MONITORING SAFE SUCTION SYSTEMS MO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW [17. SELF MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> ❑8. DAILY VISUAL MONITORING <br /> [19. BIENNIAL INTEGRITY TEST Al GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> I]c. NO AUTO PUMP SHUTOFF Oc. NO AUTO PUMP SHUT OFF <br /> ❑11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT <br /> OFF OR RESTRICTION ❑11.AUTOMATIC LEAK DETECTOR <br /> ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) [112.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVTTY SYSTEM <br /> ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF [114.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> [115. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW I5.AUTOMATIC LINE LEAK DETECTOR 30GPH TEST) <br /> SHUT OFF OR RESTRICTION ( T) <br /> [316. ANNUAL INTEGRITY TEST(0.1 GPH) [116.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [117. DAILY VISUAL CHECK ❑17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT 468. Ell. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE [14. DAILY VISUAL CHECK 469, <br /> DATE INSTALLED ❑2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS [15. TRENCH/LINER MONITORING <br /> []3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR 6. NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the information provided herein is tme and accurate to the best of my knowledge. <br /> SIGNATUREOF0 0 E TOR DATE: 470 <br /> NAME OF OWNER/QQPERATOR(PonO: TITLEOFOWNER/OPERATOR: 472. <br /> ( ` bY'�A�e- aero <br /> Permit Number(Agency use only) 473. Permit Approved By(Agewy use only) 474, Permit Expbstion Date(Agency use only) 475. <br /> UPCF hwfwm-b(1/99)-3/4 http://www.midocs.org Re,02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.