My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:49:17 PM
Creation date
11/7/2018 10:04:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4040\PR0231963\COMPLIANCE INFO 2018 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2018 - PRESENT
QuestysRecordDate
7/23/2018 6:35:09 PM
QuestysRecordID
3946152
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://Nvww.waterboards.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Withbr the State of California <br /> Authority Cited:Cis apter 6.7,Health and Safety Code,Chapter 16,Division 3, Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pacific Gas and Electric Company Facility ID: PGE095 <br /> Site Address: 4040 West Ln. Cit,: Stockton Zip: 95204 <br /> Facilitv Contact Person: Alex Steele Contact Phone No.: (916)439-3477 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 9/20/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: Motor Oil AST Tank ID: Hydraulic Oil AST <br /> ❑ In-Tank Gaugi ng Probe. Model ❑In-TankGauging Probe. Model: <br /> ❑X Annular Space or Vault Sensor. Model: 794390-420 Annular Space or Vault Sensor. Model: 794390-420 <br /> '❑ Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: Q Tank Overfill/High-Level Sensor. Model: 794390-420 <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model it Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-TankGauging Probe. Model: <br /> ❑ .Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(,). Model: ❑Fill Sump Sensor(s). Model: <br /> I❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Lite Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> �❑ Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Vatve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Vabe(,). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility curtains more tanks or dispensers,copy this form. Include informatim for every tank and diyrenser at the fncilit}. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance Hith the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers' checklists)necessary to verih that this information is correct and <br /> a Plot Plan showing the layout of monitoring equipment.For a ny equipment capable of generating such reports,1 have also attached a copy of <br /> the report;(check alithatapply) : N System set-up ❑X Alarm history report <br /> Technician Name(print): Pat Banbury Signature: Pat Eaouuy <br /> Certification No A20465 License. No.: 588098 <br /> Testing Company Name:TAIT Environmental Services,Inc. Phone No.: 714560-8222 <br /> Testing Company Address:701 N Parkcenter Dr.,Santa Ana,CA,92705 Date of Testing/Seryicing: 9/20/2018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.