Laserfiche WebLink
DATE n' <br /> SAN JOAQUIN COUNTY PR# <br /> 0 ENVIRONMENTAL HEALTH DEPARTMENT PAGE 4 <br /> 304 E.Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Name 7fAM Facility Address q - Y �f <br /> Facilty Contact "k"'a a Title Phone # <br /> UST# ( Product $7 UST#7—ProductUS #Product _UST#_Product <br /> Overfill Prevention: 0 AudibleNis al Mechanical Monitoring Panel: �IrS 3 `sb <br /> Piping System: 0 Gravity Wessure 0 Suction Violations: inor 0 Major <br /> Automatic Pump Shut Down Satisfies CCR 2636 es 0 No Dispenser Pan: Yes D No <br /> INSPECTION TYPE: routine OMonitoring Certification DComplaint Dinstall DRemoval DRepair/Upgrade <br /> COMPANYNAME: e TECHNICIAN NAME: PHONE: <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance&monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3 CCR 2711(b)&(c) Current State Forms A&B 22 CCR 2630 (d) Annual line leak detector test <br /> 4 ✓ HSC 25292.2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2643 (d) Triennial tightness test of <br /> 6 CCR 2636 (c)(1) All releases in secondary piping suction piping that is not <br /> flow to a collection sump continuously monitored <br /> 7 HSC 25291 (e) Water in secondary(20)cont 26 CCR 2643 (e) Biennial tightness test of gravil <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for US-i <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636 (f)(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13 CCR 2635(b)(1) Spill container 31 HSC 25298 (b) Permit to temporarily close U: <br /> 14 CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed anc <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640(e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1 000'of Public Well, no ELD <br /> unauthorized release 35 CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 t/CCR 2632 (d) Monitoring &response plan 36 H&SC 25299(a)(9)Disabling leak detect. device: <br /> 19 VCCR 2712(i) Monitoring & response plan is 37 violation(s) not listed above <br /> on site U <br /> EHD INSPECTOR: PHONE: ZD'l I � > %y,7 <br /> RECEIVED BY: LE: PHONE: <br />