PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\4747\PR0232482\COMPLIANCE INFO 1993-2003.PDF
QuestysFileName
COMPLIANCE INFO 1993-2003
QuestysRecordDate
1/23/2018 8:03:31 PM
QuestysRecordID
3770094
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a -epTd Y MONITORING SYSTEM CERTIFICATION <br /> or Use By All Jurisdictions Within the State of Calofmie <br /> Authority CitdWapter 6.7,Health and Safety Code;Chapter 16,Division 3 3,California Code of Regulations <br /> This Form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is insetted at the facility, ase <br /> certification or report must be prepared for each monitring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner opera ar. a owner opera or must submit a copy o t rs orm o e local agency regulating UST systems within 30 days of test date. Instructions are printed <br /> on the back page. <br /> A. General Information <br /> FacilityName: CHEVRON 200764 <br /> Site Address: 4747 WEST LANE City: STOCKTON CA ZIP: 95210 <br /> Contact Phone No: 956-2520 <br /> Facility Contact Person: MANAGER Date of Testing/Service: 03/26/2001 <br /> Make/Model of Monitoring System:VEEDER ROOT TLS Word Order Number: 2216067 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicate specific equipment inspected/serviced <br /> Tank ID: SUPER TanklD: PLUS <br /> -39 In-Tank Gauging Probe. Model: TLS In-Tank Gauging Probe. Model: <br /> 71 Annular Space or Vault Sensor. Model: TLS Annular Space or Vault Sensor. Model: TLS <br /> -39 Piping sump/rrench Senors). Model: TLS Piping Sump/Trench Sensor(s). Model: TLS <br /> Fill Sump Senors). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> 71 Electronic Line Leak Detector. Model: TLS PLLD Electronic Line Leak Detector. Model: TLS PLLD <br /> Tank overfill/High-Level sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Dispenser containment Sensor(s) Model: TLS Dispenser Containment Sensors) Model: TLS <br /> shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chains(s). Dispenser Containment Float(s)and Chains(s). <br /> Other(specify equipment type and model in section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> an : REGULAR an <br /> -39 In-Tank Gauging Probe. Model: TLS In-Tank Gauging Probe. Model: <br /> -XIAnnular Space or Vault Sensor. Model: TCS-- Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: TCS Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: TLS PLLD Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> -39 Dispenser Containment Sensor(s). Model:TCS Dispenser Containment Sensor(s). Model: <br /> Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chains(s). Dispenser Containment Float(s)and Chains(s). <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturer's guidelines. <br /> Attached to this certification is information(e.g manufacturer's checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up report; ® Alarm history report <br /> PRINTED NAME: ANEIL CHAND SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)80011633 <br /> page 1 of 3 Based on CA form dated 05/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.