My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1993 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
9484
>
2300 - Underground Storage Tank Program
>
PR0232601
>
BILLING 1993 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2024 11:06:28 AM
Creation date
11/7/2018 10:40:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1993 - 2006
RECORD_ID
PR0232601
PE
2361
FACILITY_ID
FA0004525
FACILITY_NAME
West Lane Chevron
STREET_NUMBER
9484
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09055063
CURRENT_STATUS
01
SITE_LOCATION
9484 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST\9484\PR0232601\BILLING 1993 - 2006.PDF
QuestysFileName
BILLING 1993 - 2006
QuestysRecordDate
4/11/2018 6:53:39 PM
QuestysRecordID
3851726
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> + f� UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM, °�•a�N'' <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM 2 INTERIM PERMIT I7 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE <br /> ❑ 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: j <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN C � <br /> A. OWNER'S TANK I.D.# 1 <br /> f B. MANUFACTURED <br /> D. <br /> C. DATE INSTALLED(MO/DAY YEAR) 1 <br /> D. TANK CAPACITY IN GALLONS: f <br /> II.TANK CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. ` <br /> A. 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. G is REGULAR 3 DIESEL <br /> 2 PETROLEUM ❑ UNLEADED ❑ 6 AVIATION GAS <br /> 80 EMPTY Iy�a[T 1 PRODUCT ib PREMIUM 4 GASAHOL <br /> r l UNLEADED ❑ 5 JET FUEL <br /> ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED 7:1 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br /> C.A.S.x: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LONER ID g5 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM1718 IDD% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) 71g BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ <br /> 99 OTHER <br /> ❑ <br /> C.INTERIOR 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING q 4 PHENOLIC LINING <br /> ❑ 5 GLASS LINING �6 UNLINED ❑ <br /> LINING ❑ 95 UNKNOWN 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YESX NO— }, <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP �Ic]f 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN j❑`�99 OTHER <br /> E.SPILL AND OVERFILL. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A PRESSURE d U' 3 G�RA � <br /> p U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A 2 DOUBLE WALL A U 3 A U 95 UNKNOWN d U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)AOI7 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN <br /> A U 99 OTHER <br /> D. LEAK DETECTION 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING S I A <br /> MONffORING ❑ 99 OTHER <br /> V.TANK LEAK_DETECTION <br /> 1 VISUAL CHECK Q 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMAT D AT ST USED(MOIDAY/YRy =ESTIMATEDNTITY OF 3.WAS TANK FILLED WITH <br /> MAINING GALLONS INERT MATERIAL? YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED A SIGNATUREI DATE <br /> LOCAL AG ENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.a.# <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORM B (12-91) <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FOR0034B.R6 <br />