BILLING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST RIPON
>
10858
>
2300 - Underground Storage Tank Program
>
PR0231768
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/9/2024 4:33:23 PM
Creation date
11/7/2018 10:42:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0231768
PE
2381
FACILITY_ID
FA0003868
FACILITY_NAME
DEN DULK POULTRY
STREET_NUMBER
10858
Direction
E
STREET_NAME
WEST RIPON
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
25724041
CURRENT_STATUS
02
SITE_LOCATION
10858 E WEST RIPON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\W\WEST RIPON\10858\PR0231768\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/30/2017 5:05:42 PM
QuestysRecordID
3708111
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI(a WATER RESOURCES CONTROARD <br /> FORM 'B': UNDE GROUND STORAGE TANK PRO RAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. a Z <br /> MARK ONLY ❑ ❑ L..�'❑ 1 O <br /> 1 NEW PERMIT 3 RENEWAL PERMIT CHANGE OF INFORMATION 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT E:] 6 TEMPORARY TANK CLOSURE ❑B TANK REMOVED <br /> CAL/ <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: JO&C FARM TANK-YES❑ NOEj;. (� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY A <br /> co <br /> A. OWNERS TANK ID# L B. MANUFACTURED BY: <br /> C. YEAR INSTALLED L)Ak, D. TANK CAPACITY IN GALLONS: QCJIII <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PET OLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED ❑ 3 DIESEL <br /> F-13 CHEMICAL PRODUCT OIL F-11 PRODUCT [:]4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑BO EMPTY ❑95 UNKNOWNASTE ❑7 METHANOL E jM-tTTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF �� C) <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.q C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BO%A,B,C,&D <br /> A. TYPE OF ❑ 1 DOUBLEWALLED F—] 3 SINGLE WALLED WITH EI(TERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM INGLEWALLED ❑4 SECONDARY CONTAINMENT 99 OTHER <br /> 1 STEEUIRON ❑2 STAINLESS STEEL 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE F-� 7 ALUMINUM ❑B 100%METHANOL COMPATIBLE FOP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C, INTERIOR <br /> F-] 1 RUBBER UNED 2 ALKYD LINING 3 EPDXY LINING 4 PHEN LIC LINING <br /> LINING F-]5 GLASS LINING ❑ 6 UNLINED NKNOWN <br /> ❑ IS UNING MATERIAL COMPATIBLE WITH I!96 HANOL? ❑YES ❑ NO ❑ - <br /> D. CORROSION ❑ 1 POLYEfHLENE WRAP 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDER OUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> S.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINEDTRENCH A U 9/ NONE A IU 6 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FISERGLASSPIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A 695 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 1 P 8 1 VISUAL CHECK P 6J 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> I8 6 PRECISION TESTING P S 7 PRESSURETESTING P 8 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> I. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED( [YR)/ 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> �}��/ SUBSTANCE REMAINING IN 13ALLON8 INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS dEEb COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> ENI = = I '1 6 g <br /> CURRENT LOCAL AOENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> •DAN 1 <br /> PERMIT NUMBER PERMIT APPROVAL DATE PER&iFrEXPIRATION D <br /> CXECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE I.RECEIPT# BY: <br /> FORM B(6-29-66) THIS FORM MUST BE ACCOMPAN199P.Y A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A RENT FORM'A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />