Laserfiche WebLink
8OA1l0 OF TRUSTEES SAN JOAQUIN LOCAL HEALTH DISTRICT SERVING <br /> isms* Culbertson. Pres. t City of Lodl <br /> f'alrlcla E. Vannuccl. Secy. 1601 East Hazelton Avenue, P. O. Box 2009 San Joaquin County <br /> Anlhonelt•Van Spronsen City of Escalon <br /> Earl Plmen(el Stockton, Callfornla95201 City of Manteca_ <br /> Fern dupbse209/466-6781 City of Ripon <br /> Daniel L. Flores City of Stockton <br /> John 0. Most. M.O. City of Tracy <br /> William J. Wade Jogl Khanna. M.O.. M.P.H.. District Health Officer San Joaquin County <br /> Mary Anna Lova San Joaquin County <br /> Facility Name rn nLf- ryV �`' <br /> al ell- <br /> Address ;)-- ( ";L� <br /> Date of Inspection Inspector -%� <br /> MONITORING ALTERNATIVE #7 <br /> Limited to underground storage tanks which have infrequent inputs and withdrawals and <br /> where the liquic: level in the tank can be measured to an accuracy of +5 gallons or less <br /> when the tank is half full . <br /> This monitoring alternative shall include: <br /> Annual precision test on tank and piping. <br /> L, Tank gauging performed as follows: <br /> Tank must be capable of being secured to prevent unauthorized inputs and <br /> /withdrawals. <br /> `' Tank must have no inputs or withdrawals for at least a 48 hour period <br /> (2 days) at the end of consecutive periods lasting up to 7 days. <br /> (For example: tank in use Monday through Friday, then locked <br /> over weekend) . <br /> L. Liquid level measurements are taken at the beginning and end of the <br /> monitoring period (lasting at least 48 hours) . <br /> (For example: level measured and recorded Friday night before <br /> locking and again on Monday morning before opening. ) <br /> L/ i level varies more than 1% of the tank volume or 5 gallons , which <br /> If liquid <br /> ever is less, between measurements, an unauthorized release shall be <br /> assumed to have occurred and shall be reported to the local agency within <br /> 24 hours, as per Article 5, Sect. 2652 of the regulations and further <br /> evaluations shall be performed to verify or disprove the variations. <br /> Implementation of the monitoring alternative requires that the following circled items be <br /> completed by the dates specified. <br /> 1 \ Precision test(s) must be performed by t hand results submitted to this <br /> office within 30 days of the test. <br /> Tank gauging must be started immediately. (See instructions above), <br /> If the above compliance dates cannot be met, contact this office prior to the specified <br /> date. <br /> 4/86 UGT 3 <br />