Laserfiche WebLink
Appendix VI RECEIVED <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://WWw.swrcb.�T.QCCOD 2018 <br /> MONITORING SYSTEM CERTIFICATION JJ <br /> For Use By All Jurisdictions Within the State of California ENVIRONMENTAL <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16,Division 3, Title 23, Ca/ifffp* p�ie�lnpgRTMENT <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#17647,MKT 2368(N-744) Bldg.No.: <br /> Site Address: 1048 W.YOSEMITE AVE@ EL PORTEL City: MANTECA Zip: 95336 <br /> Facility Contact Person: DEALER-ANTWAN Contact Phone No.: 209-239-2329 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 7/12/2018 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected serviced: <br /> Tank ID: T-1-RUL Tank ID: <br /> I✓ In-Tank Gauging Probe. Model: 846390-109 r In-Tank Gauging Probe. Model: <br /> P Annular Space or Vault Sensor. Model: 794390-409 r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: 794380-208 r Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> P Mechanical Line Leak Detector. Model: Veeder Root FX1V r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: flapper r Tank Overfill/High-Level Sensor.Model: <br /> r Other(specify equipment a and model in Section E on Pae 2). Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID: T-2-PUL Tank ID: <br /> I7 In-Tank Gauging Probe. Model: 846390-109 r In-Tank Gauging Probe. Model: <br /> P Annular Space or Vault Sensor. Model: 794390-409 r Annular Space or Vault Sensor. Model: <br /> P Piping Sump/Trench Sensor(s). Model: 794380-208 r Piping Sump/Trench Sensor(s). Model: <br /> I- Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Veeder Root FX1V r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> ry Tank Overfill/High-Level Sensor.Model: Flapper r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pa e 2). r Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-208 r Dispenser Containment Sensor(s).Model: <br /> 17 Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 3/4 Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-208 r Dispenser Containment Sensor(s).Model: <br /> P Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):r System set- <br /> up P Alarm history report <br /> Technician Name(print): Tim Elebeck Signature: <br /> Certification No.: B35252 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 7/12/2018 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />