Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> COUNTY Linda Turkatte, REHS, Director <br /> Kasey Foley, REHS,Assistant Director <br /> qc{Foar'' Greatness grows here. <br /> PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada, REHS <br /> Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> July 27, 2018 <br /> MICHAEL WALTON <br /> WALTON ENGINEERING INC oA!',N,7 <br /> PO BOX 1025 0 � 6yi <br /> WEST SACRAMENTO, CA 95691 0 � 4 <br /> Re: 7-ELEVEN INC#17647 SR0079418 <br /> 1048 W YOSEMITE AVE <br /> MANTECA, CA 95337 <br /> The San Joaquin County Environmental Health Department(EHD) has completed the review of the <br /> application for a permit to remove and replace the 87-octane and the 91-octane direct burry spill <br /> containers with OPW(OP-1 C-2100C-DEVR) 5-gallon spill containers on the underground storage tank <br /> (UST) system at the above noted address. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Zuna Barker at(209) 953-7311 to arrange the following appointments (a 48-hour notice is <br /> required for inspection appointments). <br /> • Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic test(or <br /> equivalent). Proper drainage must also be verified. <br /> • Corrosion protection: Verify corrosion protection for direct bury spill bucket prior to backfilling. <br /> Please be aware that the facility cannot receive fuel in the tank prior to the EHD inspection <br /> and approval. <br /> 4. Since concrete will be broken near the tank, a secondary containment test must be performed on the <br /> tank once concrete is poured in accordance with the manufacturer's guidelines. <br /> 5. Any individual performing the work of a service technician must meet the following qualifications: <br /> a. Possess or be employed by a person who possesses one of several permissible valid, current <br /> contractor's licenses issued by the Contractors State License Board (may be issued to the <br /> installation company), or a Tank Tester's license issued to the individual by the State Water <br /> Board, and <br /> b. Possess or work under the direct and personal supervision of an individual physically present at <br /> the work site who possesses a valid, current California UST Service Technician certificate issued <br /> by the International Code Council (ICC), and <br /> c. Possesses a valid, current certificate of training from the manufacturer(s) of the component(s) <br /> being tested, repaired, or serviced. <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />