Laserfiche WebLink
FA000050a PR0231462 SC001 07/1312017 <br />EHD 23-01 R. 09/22116 Page 2 of 4 Underground Storage Tank Program OR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax., (209) 468-3433 Web: www.sioov.oro/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />7-ELEVEN INC #17647 <br />Facility Address: <br />1048 W YOSEMITE, MANTECA <br />Date: <br />July 13, 2017 <br />On Site Records <br />204 <br />CCR 2712(1) <br />Current monitoring plan approved by the EHD not found on site <br />V <br />R <br />COS <br />205 <br />CCR 2712(i) <br />Failure to have an approved UST response plan available onsite <br />o V <br />o R <br />o COS <br />206 <br />CCR 2712 <br />Failure to comply with UST operating permit conditions <br />o V <br />o R <br />o COS <br />207 <br />HSC 25294 <br />Failed to record unauthorized release from primary containment <br />❑ V <br />u R <br />o COS <br />208 <br />CCR 2650(e) <br />Failed to notify the EHD of a reportable unauthorized release <br />o V <br />o R <br />o COS <br />209 <br />CCR 2715(c) <br />Designated operator did not inspect all required items and/or the inspection reports not completed <br />o V <br />o R <br />u COS <br />210 <br />CCR 2715(e) <br />Designated operator monthly Inspection reports not maintained on site for at least 12 months <br />o V <br />o R <br />o COS <br />211 <br />CCR 2715(f) <br />Designated operator employee training not performed or log not kept <br />o V <br />o R <br />o COS <br />212 <br />CCR 2715(f)(2) <br />Unstaffed facility failed to have or implement a training program approved by the EHD <br />o V <br />o R <br />o COS <br />213 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />in V <br />o R <br />o COS <br />214 <br />HSC 25281.5(b)(3) <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept <br />o V <br />o R <br />a COS <br />UST System Observations <br />301 <br />125292 1 <br />UST system is not operated to prevent unauthorized release. including spills and overfills <br />V <br />o R <br />o COS <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary into secondary containment (pre-Jul 2003) <br />o V <br />o R <br />o COS <br />303 <br />HSC 25290.2(4) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004) <br />n V <br />o R <br />o COS <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) <br />o V <br />o R <br />o COS <br />305 <br />HSC 25290.1(a) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained <br />in V <br />o R <br />o COS <br />306 <br />CCR 2630(4) <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity <br />o V <br />o R <br />o COS <br />307 <br />CCR 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained <br />o V <br />o R <br />o COS <br />308 <br />CCR 2636(f) <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br />o V <br />o R <br />o COS <br />309 <br />CCR 261 <br />Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product <br />o V <br />o R <br />u COS <br />310 <br />CCR 261 <br />Failure to meet monitoring requirements in lieu of annual line tightness test <br />o V <br />u R <br />u COS <br />311 <br />CCR 2638(a), 26410) <br />Failed to properly program or operate leak detection equipment <br />o V <br />o R <br />a COS <br />312 <br />CCR 2638(f) <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br />o V <br />u R <br />o COS <br />313 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failure to construct, operate, and maintain primary containment as product-tight <br />o V <br />o R <br />o COS <br />314 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failed to have secondary containment or secondary containment not tight <br />in V <br />o R <br />o COS <br />315 <br />125291 (a) <br />Water in secondary containment not removed, analyzed, and properly disposed of (prei 2003) <br />o V <br />o R <br />o COS <br />316 <br />HSC 25290.1(03), <br />25290.2 c3 <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />o V <br />o R <br />o COS <br />317 <br />CCR 2636(()(2) <br />Line leak detector not installed <br />o V <br />o R <br />u COS <br />318 <br />CCR 261 <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />o V <br />o R <br />o COS <br />319 <br />CCR 261 <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty <br />o V <br />o R <br />o COS <br />320 <br />CCR 261 <br />Overfill prevention system not present or failed to meet overfill requirements <br />o V <br />o R <br />o COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />o V <br />o R <br />o COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />o V <br />o R <br />o COS <br />FA000050a PR0231462 SC001 07/1312017 <br />EHD 23-01 R. 09/22116 Page 2 of 4 Underground Storage Tank Program OR <br />