Laserfiche WebLink
,,,,sIFIED,PROGRAM CONSOLIDATED FG,.of <br /> TANKS <br /> UNDERGROUND STORAGE TANKS TANK PAGE 1 lD11l�oa <br /> (two pages per tank) <br /> Page I of 6 <br /> TYPE OF ACTION ❑I NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one nem only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Speeifyreason-forlocaluseonly) (Specifyreason-forlucaluseonly) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) <br /> 3 FACILITY ID: 0 0 0 0 0 0 0 0 0 0 0 <br /> Chevron Station#91848 370 <br /> LOCATION WITHIN SITE(optional) 431 <br /> 1257 W.Yosemite Ave.,Manteca CA 95336 <br /> 1.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID#5- 432 TANK MANUFACTURER433 COMPARTMENTALIZED TANK [-]Yes No 434 <br /> 1 &399 OWENS CORNING If'Yss',wm laennemeforeacbconiWn t. <br /> DATE INSTALLED(YEAR/MO) 035 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 07/11/91 12,000 0 <br /> ADDITIONAL DESCRIPTION(For kneel use ony) 438 <br /> II.TANK CONTENTS <br /> TANK USE 639 PETROLEUM TYPE 440 <br /> ®1. MOTOR VEHICLE FUEL ®la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifmark4d conglac Pctroknm Type) ❑lb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑to. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Maesials Inventory page) 401 CAS#(from narndous Mmerials Inventory page) 402 <br /> [14. HAZARDOUS WASTE <br /> (Includes U: Oil) REGULAR UNLEADED 800-61-9 <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL [13. SINGLE WALL WITH U 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one nem only) EXTERIOR MEMBRANE LINER [195, UNKNOWN <br /> 02. DOUBLE WALL ❑4. SINGLE WALL IN VAULT [199. OTHER_ <br /> TANK MATERIAL-p hay,,aak ❑1. BARE STEEL 03. FIBERGLASS/PLASTIC ❑5. CONCRETE 095. UNKNOWN 444 <br /> ((hock one nae only) [12. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS [18. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(PRP) <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN M5 <br /> (Check.nem only) [12. STAINLESS STEEL [14, STEEL CLAD W/FIBERGLASS [19. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER_ <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING [11.RUBBER LINED 0 3.EPDXY LINING ❑5.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check ase nem only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ®3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN sae sae <br /> PROTECTION IF APPLICABLE PROTECTION ❑4IMPRESSED CURRENT ❑99 OTHER <br /> (Cheek one nemonly) ❑2 SACRIFICIAL ANODE (For lural use only) <br /> SPILL AND OVERFILL YEARINSTALLED 450 TYPE(bcaluseonly) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Q kali that apply) ®I SPILL CONTAINMENT03 FILL TUBE SHUT OFF VALVE <br /> ]991 ®1 ALARM OPW 61-SO-4 <br /> ®2 DROP TUBE 1991 OPW 61-SO-4 ❑2 BALL FLOAT _ ❑4 EXEMPT <br /> ®3 STRIKER PLATE Tank Mf <br /> IV.TANK LEAK DETECTION(A description ottbe monrtoring program shall be submrttodto the local agency.) <br /> IF SINGLE WALL TANK(chsok all tnat apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 450 <br /> (Cheek one nem only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER _ <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(1/99 revised) 173 Formerly SWRCB Form B <br />