My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1997 - 2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
BILLING 1997 - 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 7:56:13 AM
Creation date
11/7/2018 11:57:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1997 - 2003
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1257\PR0231463\BILLING 1997 - 2003.PDF
QuestysFileName
BILLING 1997 - 2003
QuestysRecordDate
9/14/2016 9:10:08 PM
QuestysRecordID
3192967
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
„.,IFIED PROGRAM CONSOLIDATED FGA <br /> TANKS <br /> UNDERGROUND STORAGE TANKS TANK PAGE 1 <br /> (two pages per tank) <br /> Page 1 of 6 <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one it.only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Speci"mon-forbcalumonly) (Specifymason-forlouelmeonly) ❑ STANK REMOVED 430 <br /> BUSINESS NAME(satrnatFAaurr NAMEwonA-wing ausineas As) 3 FACILITY ID: 0 00 0 0 0 0 0 <br /> Chevron Station#91848 <br /> LOCATION WITHIN SITE(optiomil 431 <br /> 1257 W Yosemite Ave.,Manteca,CA 95337 <br /> 1.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK Yes ® No 434 <br /> 1 GWENS CGRNING If-Ym',complere one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 7/11/91 12000 0 <br /> ADDITIONAL DESCRIPTION(For coral use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 639 PETROLEUM TYPE 440 <br /> ®1. MOTOR VEHICLE FUEL ®la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifmarkecloo"IerePewlwm Type) ❑Ib. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> [12. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED [14. GASOHOL [199.OTHER_ <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Haaardaue Materials?memory page) 401 CAS#(onto Harardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Ineludo use l oa) REGULAR UNLEADED 800-61-9 <br /> ❑95.UNKNOWN <br /> 111. TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Chink one ven only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> 02. DOUBLE WALL ❑4. SINGLE WALLIN VAULT [199. OTHER_ <br /> TANK MATERIAL-primrytaNs [11. BARE STEEL ®3. FIBERGLASS/PLASTIC [:15. CONCRETE ❑95. UNKNOWN 444 <br /> (Chink one i¢toonly) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FTBERGLASS ❑8. FRP COMPATIBLE W/100%METHANOL [199.OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary mass 0 1. BARE STEEL ®3. FIBERGLASS/PLASTIC ❑5. CONCRETE 095. UNKNOWN 445 <br /> (Check one veto only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/1007e METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED 3.EPDXY LINING [15.GLASS LINING [195.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ®3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN ae us <br /> PROTECTION IF APPLICABLE PROTECTION ❑4IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(Iwai use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ®1 SPILL CONTAINMENT ®3 FILL TUBE SHUT OFF VALVE <br /> 1991 ®1 ALARM OPW 61-SO-4 <br /> ®2 DROP TUBE 1998 OPW 61-SO-4 ❑2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE Tank Mf <br /> IV.TANK LEAK DETECTION(A description of the monitoring engram shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Cheek as that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 050 <br /> (Check one item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAININGFILLED WITH INERT MATERIAL? 457 <br /> 056 TANK <br /> gallons ❑Yes ❑ No <br /> UPCF(1/99 revised) 173 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.