BILLING 2004 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
BILLING 2004 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 7:59:00 AM
Creation date
11/7/2018 11:58:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2004 - 2011
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1257\PR0231463\BILLING 2004 - 2011.PDF
QuestysFileName
BILLING 2004 - 2011
QuestysRecordDate
9/21/2016 5:59:41 PM
QuestysRecordID
3194243
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r FIED PROGRAM CONSOLIDATED FOtmW <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION - TANK INFORMATION (one form per UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections I,A III,IV,and IX below) 430. <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL.. <br /> DATE UST PERMANENTLY CLOSED: 430, 1 DATE EXISTING UST DISCOVERED: - 43% <br /> I. FACILITY INFORMATION <br /> FACILITY ID a(,agency Um only) 1 1 1 -1010101-131710171 <br /> BUSINESS NAME(Same as Faciliry Name or DBA-Doing Business As) <br /> AHMED'S SONS INCORPORATED <br /> BUSINESS SITE ADDRESS 103- CITY 1W. <br /> 1257 WEST YOSEMITE AVENUE MANTECA <br /> II. TANK DESCRIPTION <br /> TANK]DO 432. TANK MANUFACTURER 433_ TANK CONFIGURATION:THIS TANK IS 434- <br /> OWENS CORNING 0 1.A STAND-ALONE TANK C4 Iaea��rr«mb <br /> ❑ 2.ONE IN A COMPARTMENTED UNIT -wrt unb. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 7/1991 12,000 1 <br /> III. TANK USE AND CONTENTS <br /> TANK USE 0 la.MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING - ❑ It.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(m Id.U,400) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281 5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL 0 95.UNKNOWN ❑ 99.OTHER(Specify): 439x. <br /> CONTENTS PETROLEUM: 0 la REGULAR UNLEADED ❑ Ic.MIDGRADE UNLEADED ❑ Ib.PREMIUM UhL.EADED 440 <br /> 0 3.DIESEL 0 5.JET FUEL 0 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL 0 9.OTHER PETROLEUM(Specify): 440x. <br /> NON-PETROLEUM:❑ 7.USED OB. ❑ 10.ETHANOL <br /> 0 11.OTHER NON-PETROLEUM(Specify): 4406. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL 0 2.DOUBLE WALL _[1 95.UNKNOWN 443. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444. <br /> ❑ 7.STEEL,INTERNAL LINING ❑ 95.UNKNOWN 0 99.OTHER(Specify),FRP a44a. <br /> SECONDARY CONTAINMENT ❑ 1.STEEL [:13.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445_ <br /> ❑ 90.NONE ❑ 95.UNKNOWN 0 99.OTHER(Specify): FRP 445e. <br /> OVERFILL PREVENTION ❑ I.AUDIBLE&VISUAL ALARMS ❑ 2 BALL FLOAT ® 3.FILL TUBE SHUT-OFF VALVE 452_ <br /> I ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVER FI LL PREVENTIONEQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL 0 2.DOUBLE WALL El 99.OTHER _ _ 469. <br /> SYSTEM TYPE 0 L PRESSURE 0 2.GRAVITY 0 3.COFIVENTIONAL SUCTION 0 4.SAFE SUCTION 123 CCR W36(e)(3)1 <br /> 458. <br /> PRIMARY CONTAINMENT 0 L STEEL ❑ 4.FIBERGLASS 0 8.FLEXIBLE ❑ to.RIGID PLASTIC 464_ <br /> -SECOND <br /> ❑ 90.NONE 0 95.UNKNOWN 0 99,OTHER FRP <br /> . . ..... ........-....-..-.......-...___.._ <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ S.FLEXIBLE ❑ lo.RIGID PLASTIC <br /> 0 90.NONE 0 95.UNKNOWN 0 99.OTHER(Specify): FRP 464c. <br /> PIPINGfFURBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL 0 2.DOUBLE WALL 0 90.NONE 46x4_ <br /> VI. VENT,VAPOR RECOVERY (VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT 0 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC 0 90.NONE 0 99'OTHER(Specify): 46 ei_ <br /> [3VENT SECONDARY CONTAINMENT L STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC 0 90.NONE 0 99.OTHER(Specify): 4�9at1 <br /> -.........................................._...._._........_......--_ -.__....._..................__....._......_......____ - _._ .. ... <br /> VR PRIMARY CONTAINMENT 0 L STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE 0 99.OTHER(Specify): .ate <br /> 1 <br /> VR SECONDARY CONTAINMENT ❑ L STEEL 0 4.FIBERGLASS 0 10.RIGID PLASTIC 0 90.NONE 0 99.OTHER(Specify): a�h <br /> l. <br /> VENT PIPING TRANSITION SUMP TYPE ❑ I.SINGLE WALL ❑ 2.DOUBLE WALL 0 90.NONE <br /> RISER PRIMARY CONTAINMENT 0 L STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC 0 90.NONE 0 99.OTHER(Specify): <br /> RISER SECONDARY CONTAINMENT 0 L STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC 0 90.NONE ❑ 99.OTHER(Specify): <br /> FILL COMPONENTS INSTALLED 0 I.SPILL BUCKET ® 3.STRIKER PLATEBOTTOM PROTECTOR 0 4 CONTAINMENT SUMP 451.. <br /> VII. UNDER DISPENSER CONTAINMENT(UDC) <br /> _CONSTRUCTION TYPE 0 1.SINGLE WALL_ _ 0 2.DOUBLE WALL ❑ 3.NO DISPENSERS 13 90.NONC^0[ a69a <br /> CONSTRUCTION MATERIAL 0 L STEEL ❑ 4.FIBERGLASS 0 10.RIGID PLASTIC ❑ 99.OTHER(Specify) C"+:;� ' <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION 0 2.SACRIFICIAL ANODE(S) 0 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the h=rdous substance stored and that the information provided k;E!5 is true, <br /> accurate,and in full compliance with legal reguirements. <br /> APPLICANT SIGNATURE DATE - tti 470. <br /> APPLICANT NAME(Print) NADEEM ARMED 971. APPLICANT TITLE MANAGER `. ""F 47 . <br /> UPCF UST-B Rev.(12/2007)-1/2 www.unidocs.org <br />