My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2004 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
BILLING 2004 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 7:59:00 AM
Creation date
11/7/2018 11:58:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2004 - 2011
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1257\PR0231463\BILLING 2004 - 2011.PDF
QuestysFileName
BILLING 2004 - 2011
QuestysRecordDate
9/21/2016 5:59:41 PM
QuestysRecordID
3194243
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k JIv D PROGRAM CONSOLIDATED <br /> �•/ ""� TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> Pae of <br /> VL PIPING CONSTRUCTION(Check as that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE M L PRESSURE 0 2.SUCTION 0 3.GRAVITY 458. 0 1.PRESSURE 0 2.SUCTION 0 3.GRAVITY 459. <br /> CONSTRUCTION/ 0 L SINGLE WALL 0 3.LINED TRENCH 0 99,OTHER 460, 0 1.SINGLE WALL 0 95.UNKNOWN 462. <br /> MANUFACTURER 0 2 DOUBLE WALL 0 95.UNKNOWN 0 2.DOUBLE WALL 0 99.OTHER <br /> MANUFACTURER A.O. Smith 461. MANUFACTURER 4(53 <br /> 0 1.BARE STEEL 0 6.FRP COMPATIBLE W/100%METHANOL ❑1.BARE STEEL 0 6.FRP COMPATIBLE W/100%METHANOL <br /> 0 2.STAINLESS STEEL 0 7.GALVANIZED STEEL 0 2.STAINLESS STEEL 0 7.GALVANIZED STEEL <br /> 0 3.PLASTIC COMPATIBLE WITH CONTENTS 0 95.UNKNOWN O 3.PLASTIC COMPATIBLE W/CONTENTS 0 S.FLEXIBLE(HDPE) 0 99.OTHER <br /> [14.FIBERGLASS 0 8.FLEXIBLE(HDPE) 0 99,OTHER 0 4.FIBERGLASS 0 9.CATHODIC PROTECTION <br /> 0 5.STEEL W/COATING 0 9.CATHODIC PROTECTION 464. [15.STEEL W/COATING 0 95.UNKNOWN 465. <br /> VIL PIPING LEAK DETECTION(Check all that apply)(A dacition ofthe mostitoling program shall be aubmiuel to the be.]agency) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466, SINGLE WALL PIPING 467. <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP [11. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> SHUT-OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION <br /> +AUDIBLE AND VISUAL ALARMS. +AUDIBLE AND VISUAL ALARMS. <br /> 02+ MONTHLY 0.2 GPH TEST 0 2, MONTHLY 0.2 GPH TEST <br /> [13. ANNUAL INTEGRITY TEST(0.1 GPH) 03. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [14. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING [15. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): [16. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> [17. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW 07. SELF MONITORING <br /> [19. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> 0 8. DAILY VISUAL MONITORING <br /> O 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> 0 a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a. AUTO PUMP SIM OFF WHEN A LEAK OCCURS <br /> 0 It. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> 0c. NO AUTO PIMP SHUT OFF Oc. NO AUTO PUMP SHUT OFF <br /> 0 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT 0 11 AUTOMATIC LEAK DETECTOR <br /> OFF OR RESTRICTION <br /> 0 12. ANNUAL INTEGRITY TEST(0.1 GPH) 0 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> 013. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS 013.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> 014. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF [114.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> 015. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW 0 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> SHUT OFF OR RESTRICTION <br /> 016. ANNUAL INTEGRITY TEST(0.1 GPH) 0 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 0 IZ DAILY VISUAL CHECK 0 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT 468. 0 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE [14. DAILY VISUAL CHECK 469, <br /> DATE INSTALLED 0 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS 0 S. TRENCHILINER MONITORING <br /> Unknown DISPENSER 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR 0 6. NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the i ormation ovided herein is true an accurate to the best of my knowledge. <br /> SIGNATURE OF O OF OR DATE: Ona <br /> NAME OF OR/OPERATOR(pr0t) MIC ael Walton TITLE OF OWNER/OPERATOR: Contractor eR. <br /> Permit Number(Agency use only) 473 1 Permit Approved By(Agency use only) 474. Permit Expiration Date(Agency use only) 475. <br /> UPCF hwfwre-b(I/99)-3/4 http://www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.