My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2004 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
BILLING 2004 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 7:59:00 AM
Creation date
11/7/2018 11:58:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2004 - 2011
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1257\PR0231463\BILLING 2004 - 2011.PDF
QuestysFileName
BILLING 2004 - 2011
QuestysRecordDate
9/21/2016 5:59:41 PM
QuestysRecordID
3194243
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`"i 1 <br /> JNYFfED PROGRAM CONSOLIDATED t&Mw' < ` U6 <br /> TANKS CC <br /> UNDERGROUND STORAGE TANKS - TANK PAGE I <br /> (Two pages pI�) <br /> Page_of_ <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ® 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT Equipment Modification ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify recon) (specify reawn) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(S.as FACILITY NAME or DBA-Dning Business As) 3, FACILITY ID: I' <br /> Ahmed s Chevron <br /> LOCATION WITHIN SI IE(optimal) - _ %] �E7� 431' <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# °32. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK Yes No 43402� . <br /> Unknown If"Yes,"complete one page for each containment <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436, NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> Unknown 12,000 1 <br /> ADDITIONAL DESCRIPTION(For Imal use rely) 4J9, <br /> IL TANK CONTENTS <br /> TANK USE 439- PETROLEUM TYPE "a. <br /> ® 1. MOTOR VEHICLE FUEL ❑]a. REGULAR UNLEADED / ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) ❑Ib PREMIUM UNLEADED ®3. DIESEL [16. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (hem H dms Materials Inventory page) 401 CAS#(tam Hazardous Maarals Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE <br /> (1xmda used oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER [195. UNKNOWN <br /> ®2. DOUBLE WALL [14. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primarytent, [11. BARE STEEL [13. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD WNIBERGLASS ®8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ®8. FRP COMPTIBLE W/100%METHANOL 0 95.UNKNOWN ms. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED 3.EPDXY LINING ❑5.GLASS LINING 95.UNKNOWN a46. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING [14.PHENOLIC LINING ®6.UNLINED [199,OTHER <br /> Check one item onl <br /> OTHER CORROSION I.MANUFACTURED CATHODIC 3,FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN secs. DATE INSTALLED a4p. <br /> PROTECTION PROTECTION [14.IMPRESSED CURRENT [199.OTHER <br /> (if Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450, TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT Unknown ❑ 1.ALARM ®3.FILL TUBE SHUT OFF VALVE Unit <br /> ®2.DROP TUBE Unknown ❑2.BALL FLOAT ❑4.EXEMPT <br /> 10 3,STRIKER PLATE Unknown <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3. CONTINUOUS ATG ❑7.GROUNDWATER [13.MANUAL MONITORING <br /> [3 4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING [199. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455_ ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 453. <br /> gallant, ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-114 http://www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page