Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
BILLING 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 10:34:31 AM
Creation date
11/7/2018 12:01:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2012-2015
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1434\PR0231465\BILLING 2012-2015.PDF
QuestysFileName
BILLING 2012-2015
QuestysRecordDate
6/26/2017 3:07:01 PM
QuestysRecordID
3465007
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UN IED PROGRAM CONSOLIDATED FORM pC <br /> F,. UNDERGROUND STORAGE TANK RECD DECO 52012 <br /> ONITORING PLAN - (Page 1 of 2) <br /> TYPE OF ACTION 1.NEW PLAN 490-1. <br /> ❑ ® 2.CHANGE OF INFORMATION <br /> PLAN TYPE ® L MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 400-2. <br /> heck one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) I. <br /> BUSINESS NAME(Same as Facility Name or DBA) Tower Mart# 886 3 <br /> BUSINESS SITE ADDRESS 1434 W Yosemite Ave. 103T CITY Manteca NCA 95337 la. <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibmtion of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers'instructions,or annually,whichever is more frequent.Such work must be performed by qualified personnel.123 CCR§2632,2634,2639,26,111 <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 4.3 <br /> 490db, <br /> III. MONITORING LOCATIONS <br /> ❑ L NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,26341 490-4. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) "'ck apply)that 1l <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 990-5 <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632.26341 <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 49 <br /> PANEL MANUFACTURER: Veeder-Root 490-7. MODEL#: TLS 350 490-8. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490'9 MODEL#(S):794390-420 490.1. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§26431 49.]L <br /> PANEL MANUFACTURER: 490"12 MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490.14 MODEL#(S): 49.15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16' <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17' <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 49.9918. <br /> 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.1] 49x20, <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§z 5] TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURSn90.P921. <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.1] 490-23. <br /> TEST FREQUENCY: ❑ a ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 4W25 <br /> ❑ 99.OTHER(Specify): 4 42. , <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) = <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490'28. <br /> In CCR SECONDARY CONTAINMENT IS: 490-z9. <br /> §2636] ® a DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM <br /> PANEL MANUFACTURER:Veeder-Root 490.30 MODEL#: TLS 360 4%-31. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 990.32- MODEL# 0794380-208 490-33, <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 49.34' <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a YES ❑ It.NO 490-35. <br /> ® 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36, <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MLLDMANUFACTURER(S): VMS 490-34- MODEL#(S):Vaporless,LD-2000 490-38. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 49.39. <br /> ELLD MANUFACTURER(S): 490-00. MODEL#(S): 490'11 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490.41 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 49.43. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 49.44. <br /> ❑ 4.PIPE INTEGRITY TESTING. 49045. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) g94W 46 <br /> ❑ 5.VISUAL PIPE MONITORING. 49.49. <br /> FREQUENCY: - ® a.DAILY ❑ It.WEEKLY ❑ a MIN.MONTHLY&EACH THdE SYSTEM OPERATED. 49.49hp , <br /> •Allowed for monironn efunbuned emer mentor fuel piping oN er HSC 25281.5 3 <br /> 6.SUCTION PIPING MEETS EXEMPTION CRITERIA[z3 CCR g2636(.)(3p 49s0. <br /> 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 49.51 <br /> ❑ 99.OTHER(Specify) 49.52. <br /> 49.53, <br /> UPCF UST-D(12/2007)-1/4 w .nnidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.