My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985 - 2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
420
>
2300 - Underground Storage Tank Program
>
PR0231458
>
BILLING 1985 - 2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 4:49:40 PM
Creation date
11/7/2018 12:20:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985 - 2001
RECORD_ID
PR0231458
PE
2361
FACILITY_ID
FA0001196
FACILITY_NAME
SAVE ON FUEL
STREET_NUMBER
420
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
219-312-06
CURRENT_STATUS
01
SITE_LOCATION
420 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\420\PR0231458\BILLING 1985 - 2001.PDF
QuestysFileName
BILLING 1985 - 2001
QuestysRecordDate
5/22/2018 6:23:57 PM
QuestysRecordID
3899688
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN WATER RESOURCES CONTR OARD <br /> FORM 'B': UNDGROUND STORAGE TANK PROGRAM ,..., mo <br /> TANK PERMIT APPLICATION INFORMATION <br /> TANK COMPLETE A SEPARATE FORM WITH THE FOLLOWI G INFORMATION FOR EACH TANK. z <br /> I� <br /> MARK ONLY ❑ 1 NEWPERMIT ❑ 3 RENEWALPERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑B TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: �. GSt�.Nl�Y FARM TANK•YES❑ NO IV <br /> W <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY C0 <br /> W <br /> A. OWNERS TANK ID IT O3 B. MANUFACTURED BY'. <br /> C. YEAR INSTALLED uw D. TANK CAPACITY IN GALLONS: 0 <br /> II. TANK C NTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,PFOMPLETE ITEM D. <br /> A. MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B C. 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM O,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.#'. <br /> HAZARDOUS SUBSTANCE STORED&CAS # <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ 8100%METHANOL COMPATIBLE FRP <br /> MATERIAL ❑9 BRONZE ❑ 10 GALVANIZED STEEL UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING n 4 PjIENOLIC LINING <br /> C. INTERLININ OR ❑ 5 GLASS LINING ❑ 6 UNLINED UNKNOWN <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 700%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 INYLWRAP E] 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION El 91 NONE 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM ACONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 5 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1VISUAL CHECK5 2 INVENTORY RECONCILIATION P S 3VADOSEWELLS P S 4 ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE cip, P S 95 UNKNOWN P S 99 OTHER <br /> V1. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/VRI 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) - DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> INWq <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERM EXPIRATION DATE <br /> CHECK M PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FnRM R IR-29-991 THIS FORM MUST BE ACCOMPANIE FACILITY/SITE APPLICATION, FORM 'A',UNLESS A NORENT FORM'A' HAS BEEN FILED <br />
The URL can be used to link to this page
Your browser does not support the video tag.