Laserfiche WebLink
4wf <br /> NIFIED PROGRAM CONSOLIDATED FO TANK:TA0508397 <br /> 2 V' PR#: PRO505151 <br /> UNDERGROUND STORAGE TANKS -TANK VAGE,1 FAC#: FA0007815 <br /> (two pages per rank) <br /> Page 4 of7 <br /> TYPE OF ACTION <br /> ❑ ?NEW SITE PERMIT ❑ 4AMENDED PERMIT 14SCHANGE OF INFORMATION ❑ 6TEMPORARY SITE CLOSURE <br /> (n1 My ttwnmy) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3RENEWAL PERMIT ❑ 8TANK REMOVED 430 <br /> BUSINESS NAME(swt.eFAcarryNAME m DSA-Doing S:winea A:) FACILITY m: PR#: 1 <br /> PONTES QUICKI-KLEEN CAR WASH' FA0007815 PR0505151 <br /> LOCATION WITHIN SITE(optica) 707 E YOSEMITE AVE,MANTECA 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan With the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 5 43z I TANK MANUFACTURER 433 COMPARTMENTALIZED TANK s ❑No B3 <br /> TA0508397 TIPSA v-va:onyl<u mevage rm e.H�ca,patmawl <br /> DATEIN ALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS r� 437 <br /> od 4! 5,000 ? <br /> ADDITIOAIAE DESCRIPTION(Fxm a vniy) 438 <br /> U.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® I.MOTOR VEHICLE FUEL ❑ la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (Rnwhdm I.Pcaokmn Type) ® Ib.PREMIUMUNLEADED ❑3.DIESEL ❑ 6.AVIATIONFUEL <br /> ❑ 2.NON-FUELPETROLEUM ❑ Ic MIDGRADEUNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME 011 ss M-,m-E lmmtarypage) 441 CAS#(uom 33aatdww mwwVab lmmtwy page) 442 <br /> ❑4.HAZARDOUS WASTE <br /> (1a tJaeg oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> ( _ ) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> ®2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIA.-prima"nk tz I.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ,-.i 95.UNKNOWN 444 <br /> (CTNwrc i dy) ❑ 2.STAINLESS STEEL ❑ STEEL Cl-ADW/FIBERGLASS ❑ S.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-wcondary tank ❑ I.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 445 <br /> (CLwk wwitrn mly) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ S.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL99.OTHER !I^i) <br /> ❑ 5.CONCRETE v� <br /> TANK INTERIOR LINING ❑ E RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED N7 <br /> OR COATING <br /> (C me imnmly) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ❑ 6 UNLINED ❑ OTHER <br /> (Fa tont we my) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC E]95 UNKNOWN Ma DATEINSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (c> "ftanmly) ❑ 4IMPRESSED CURRENT ❑99OTHER <br /> ❑ 25ACRIFICIAL ANODE (Fm lod qac my) <br /> SPILL AND OVERFIILLLL YEAR INSTALLE450 TYPE(localmcmly) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Clwrk ill caw apply) Ijx I SPILL CONTAINMENT ❑ IALARM3 FILL TUBE SHUT OFF VAD <br /> �2DROP TUBE E] 2BALL ❑ 4EXEMPT <br /> M\3 STRIKER PLATE FLOAT <br /> TV.TANK LEAK DETECTION(A dwwpdmofd monitomgv�:IwnIK:&w:imam us lo®ly y.) <br /> IF SINGLE WALL TANK B k all tlut q y) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Clink w¢nvnwJY) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ STANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ "OTHER <br /> V.TANK CLOSURE INFORMATION J PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK tILLEDWIrHMERT MATERIAL? 457 <br /> 0.00 gallons ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />