My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1999 - 2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
BILLING 1999 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2023 4:17:13 PM
Creation date
11/7/2018 12:22:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1999 - 2005
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\707\PR0505151\BILLING 1999 - 2005.PDF
QuestysFileName
BILLING 1999 - 2005
QuestysRecordDate
7/15/2016 9:11:07 PM
QuestysRecordID
3143768
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
go 5 <br /> `nJNIF1ED PROGRAM CONSOLIDATED FORrw! TANK: TA05083% <br /> PRM: PRO505151 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 FAC N: FA0007815 <br /> VI.PIPING CONSTRUCTION(C1 kali Naz apphl Pap,3 o82 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ® I.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 458 ❑ L PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 459 <br /> CONSTRUCTION ❑I.SINGLE WALL ❑3.LIKED TRENCH ❑ 99.OTHER 460 ❑ I.SINGLE WALL ❑ 95.UNKNOWN 462 <br /> ®2 DOUBLE WALL E:195.UNKNOWN ❑ 2.DOUBLE WALL ❑ 99.OTHER <br /> MANUFACTURER A O SMITH 461 MANUFACTURER 463 <br /> ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE W 1 W%METHANOL ❑ L BARE STEEL ❑ 6.FRP COMPATIBLE W I OOY.MEDIANOL <br /> ❑ 2.STAINLESS STEEL ❑ T.GALVANIZED STEEL ❑ 2_STAINLESS STEEL ❑ ].GALVANIZED STEEL <br /> ❑ PLASTIC COMPATIBLEW/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN <br /> ®4.FIBERGLASS ❑8.FLEXIBLE(HDPE) ❑ 99.OTHER ❑4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER <br /> ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 460 ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION <br /> 465 <br /> VII.PIPING LEAK DETECTION(Oxtkall0w awh)(A am�imbn n[u9 mmcmiinR progom alWl ce 4amnitaa m Ore 19ra1 agmwy_) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING <br /> 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Cheek all that apply); <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ I.ELECTRONIC LIKE LEAK DETECTOR 3 0 GPM TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑2.MONTHLY 0 2 GPH TEST ❑ 2.MONTHLY 0.2 GPH TEST <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑ 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) ❑ 6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS ING VALUES IN BELOW GROUNDPIPING): <br /> ❑7.SELF MONITORING <br /> ❑ T.SELF MONITORING <br /> GRAVITY FLOW <br /> ❑9.BIENNIAL INTEGRITY TEST(0.1)GPH GRAVITY FLOW(Check all that apply): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check dl that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(C an) ALARMS AND(Cb-) <br /> ® a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ® b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑c NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ❑ <br /> IL AUTOMATIC LINE LEAK DETECTOR Ll 0 GPH TEST)WIT FLOW SHUT OFF OR ❑ 11 AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPM ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all Dur apply) EMERGENCY GENERATORS ONLY(Check all tbar apph) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHAT OFF• ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑S15.AUTOMATIC LINE LEAK DETECTOR(3 0 GPH TEST)WITHOUT FLOW E] 15.AUTOMATIC LINE LEAK DETECTOR(3 0 GPH TEST)WITHOUT FLOW <br /> HUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPM <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VILL DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 068 ❑ 2,CONTINUOUS DISPENSER PAN SENSOR AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ® 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS 4M <br /> IX.OWNER/OPERATOR SIGNATURE <br /> Ica h&A the infonrurim pmvidcd Mrein is rsuc and auar b the best olms'kmrrl ge. <br /> SIGNAT REOFOWNER/OPERATOR DATE 470 <br /> NAME OF WNER/OPERATOR(print) /_ TITLE OF OWNER/OPERATOR <br /> �S Cid Y��1 47t 472 <br /> Permit N.m (Forkazluseonh) 473 Nm6Appr (Forloolusemly) 474 P. ,t E%pirslm Wre(Forlo[aluxmb) 475 <br /> PT0005454 EE0003804 12/31/1998 12:00:OOAM <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.