My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1994 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO 1994 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 1:43:59 PM
Creation date
11/7/2018 12:24:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994 - 2009
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\824\PR0231459\COMPLIANCE INFO 1994 - 2009.PDF
QuestysFileName
COMPLIANCE INFO 1994 - 2009
QuestysRecordDate
2/16/2017 6:45:24 PM
QuestysRecordID
3339010
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
240
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. 0L2/23/2008 12:27 FAX 8257722 MANTECA SHELL 10003 <br /> 40 of <br /> Monitoring System Certification *M—c <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 5.00 <br /> Com tete the following checklist: <br /> fad Yes 0 No* I Is the audible alarm o erational7 <br /> IKI Yes ❑ No* Is the visual alarm operational? <br /> ®Yes Q No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> 0 Yes 0 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> 0 Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> ® N/A operational? <br /> [s1 Yes Q No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> 0 N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; 181 Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sonsor failure/disconnection? 0 Yes; ❑No. <br /> ❑ Yes ❑ No' For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> 10 N/A. mectmnical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill ort sand eratinproperly? if so at what ercemDftank.ca aci does the alarm.tri r7._ % <br /> 'M Yes' ❑ No Was any monitorurg equipmem,repiaceiM Yfyes,idemlfy-sptctfresensors;prubes,vr`dtheregnipmentrepieced <br /> and list the manufacturer name and model for all replacement parts in Section E below. <br /> IM Yes* ❑ No Was liquid found inside any sccondary containment systems designed as dry systems? (Check all that apply) <br /> U Product; lM Water. If yes,describe causes in Section E below. <br /> 0 Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> 0 Yes 0 No* Is all monitoring equipment oerational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or win be corrected. <br /> E. Comments: I rel�roaramm d the output relays to properly reconnlze sumo and pan sensors fol_ <br /> nositive shut-down and fall safe. <br /> Removed less than 1 gal of rain water from the 87 sumo. <br /> UN-036-2/4 Page 2 of 4 Rev.o6M4/01 <br /> www.Imldocn.orY <br />
The URL can be used to link to this page
Your browser does not support the video tag.