SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, Califomia 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www siaoy.OrC/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Quick & Easy Food Mart Fadldy 824 East Yosemite Ave, Manteca nBpection Jun 28, 2013 <br /> Name: Address: Date: <br /> VIOLATIONS <br /> # C7 I C2 M I Code Section HSC=CA Health and Cade;CFR=Cade d Federal R ulatiore <br /> Ct=Class 1 vidation;C2=Gass 2 vidalion:M=Minor violation <br /> On Site Records(continued) <br /> 204 X CCR 2715(c) Designated operator monthly inspection:(1)alarms not documented:(24)spill containers,UDCs,and sumps <br /> life,necessa not ins cted; 5 required test dates not checked or noted; 6 employee training not verified <br /> 205 X CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br /> 206 CCR 2715(f) Designated operator employee training:(1)not performed;(2)not current for at least one employee on site; <br /> 3 log not kept <br /> 207 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily lex log not kept <br /> Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(M7) <br /> 303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br /> 304 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (Mf) <br /> 305 CCR 2636(t)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates an (M1) <br /> audible and visual alamn or stops flow of product at the dispenser when it detects a leak <br /> 306 CCR 2631(a) Primary containment is not product tight <br /> 307 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> 309 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (1112) <br /> 310 HSC 25291(a) Water in 2-containment not removed,analyzed&property disposed of <br /> 311 CCR 2636(f)(2) Line leak detectors)not installed or failed to detect a 3-gallon per hour leak at 10 psi (11111) <br /> 312 CCR 2635(b) No spill container or overfill prevention system installed (1112) <br /> 313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means to keepI(M2) <br /> the spill container em <br /> 314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements 315 HSC 25299(%2) Tampering with or disabling leak detection devices or alarms <br /> 316 CCR 26311(a) UST system is rot compatible with the substance stored <br /> 317 HSC 25298(a) Illegally abandoned UST system <br /> AB 1702(2003-2004) HSC 25290.1(installed between 07101103 and 06130104) <br /> H ma HSC 25290.7 installed on or after 07/01104Compatibility and permeability requirements:(a)UST system is not compatible with the substance store401 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and( ) <br /> for a UST system installed after July 1,2004,were not submitted <br /> 402 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 403 HSC 25290.1(c)(2) $econdary containment not liquid or vapor tight <br /> HSC 25290-2(c)(2) <br /> 404 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 405 HSC 25290.1(d) Monitoring system not maintained to detect water inW Sion into the secoMary containment,or the entry of <br /> HSC 25290.2(d) Ii uid or vapor from the rima containment into the seconds containment <br /> 406 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the <br /> UST s tem not maintained <br /> 407 HSC 25290.1(1) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> HSC 252902 ipressure test approved by SWRCB; 3 test method deemed equivalent to If I or 2 by the SWRCB <br /> Emergency Generator Systems <br /> 507 CCR 2836(f)(6) Emergency generator mondoring system not checked daity or log not kept it no leak detector (M1) <br /> 502 1 HSC 25281.5(b)(3) Unburietl fuel piping not visually inspected at least monthly or log not kept (M1) <br /> USTs In a Vault <br /> 601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br /> 602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br /> 603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br /> 604 HSC 25283.5(a)(5) UST installed after July 1,2003,does not meet or exceed applicable sections of HSC 25291 <br /> Non-Preasurized Piping <br /> 701 CCR 2643(d) Deity monitoring of suction piping(pre-January 1,1984)not performed IM1) <br /> Inspector. Reoei d By: Tee: ,I <br /> Thuy Tran (209) 468-8257 <br /> EHD 23-02 Rev 04/19/12 Page 2 UST INSPECTION REPORT <br /> 0 0 <br />