My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 2:02:53 PM
Creation date
11/7/2018 12:28:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\824\PR0231459\COMPLIANCE INFO 2013 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
2/21/2017 6:51:40 PM
QuestysRecordID
3341688
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK SYSTENPECEIVED <br /> DESIGNATED UST OPERATOR MONTHLY INSPECTION REIM 2014 <br /> Facility Name: Manteca Kwik Sery Inspection Date: July 15, <br /> Facility Address: 824 E Yosemite Ave City: Manteca DEPART LTkf <br /> Name of Designated UST Operator Conducting Inspection: Alex Jabbari <br /> International Code Council Certification No.: 5243897-UC Expiration Date: 10/6/2014 <br /> Signature: O Phone: (925) 389-1262 <br /> N/A=Not Applicable <br /> Item MONITORING PANEL/ALARM HISTORY Yesi No I N/A <br /> 1. Is the monitoring stem powered on and in proper operating mode? 0 L1 Li <br /> 2. Is the monitoring stem not currently showing any leak alarms? <br /> 3. Is the Alarm History Report/log for the previous month available,and has it been reviewed by the <br /> Designated UST Operator? (Attach a copy of the alarm history report/logreport1log to this ins ection ora) <br /> 4. Has each alarm for the previous month been res onded to appip riatel ? ® ❑ ❑ <br /> UST SYSTEM INSPECTION <br /> 5. Are tank-top containment sumps free of water,debris, and hazardous substance? Note:If the answer to Item 4 was "Yes,"or <br /> "NA"skip to Item 6 Sumps where an alarm has occurred in the past month must be inspected if a qualified service technician has not responded <br /> to,and properly addressed,the cause ofthe alarm.Documentation g nappropriate service should be attached to this re rt. <br /> L7: UDC 314 fuel alarm Yes No __,;� F No Sumps alarm Yes No <br /> Sum Location: ate: Sum Location: <br /> Sump Location: Li El - I Sump Location: 10 1 Li <br /> 6. Ares ill buckets(containment structures)free of water,debris,and hazardous substance? <br /> Yes No NJA Yes No N/A <br /> Tank 1 ID—Regular ❑ Tank 3 ID—Premium El El <br /> Tank 2 ID—Plus I ® I U I Lj I Tank 4 ID— <br /> 7. Are under-di enser containment areas free of water,debris,and hazardous substance? <br /> Yes I No I N/A I a No N/A <br /> -Dispenser— 1/2 1 El I El I Dispenser—9/10 0 1 ❑ <br /> -Dispenser—3/4L)i user-11/12 ❑ <br /> Di ser—5/6 ® EJIH Dispenser— 13/14 <br /> Dispenser—7/8 N Ll I LJ I Dispenser—15/16 <br /> 8. Leak detection is properly located within under-dispenser containment <br /> Yes No N/A Yes No I N/A <br /> Dispenser—1/2 1 Lj I Dispenser-9/10 <br /> Di ser-3/4 D nser-11/12 <br /> Dispenser—5/6 M L1 0 1 Dispenser— 13/14 <br /> Dispenser—7/8 ® I ❑ I ❑ I Dispenser— 15/16 ❑ ❑ <br /> PAPERWORK INSPECTION Yes No N/Al Date Done <br /> 9. Monitoring System Certification was completed within the past 12 months? ® ❑ ❑ 6/30/204 <br /> 10. Secondary containment tests completed within the required time frame? ❑ 10117/20113 <br /> 11. Spill bucket(containment structure)testing completed within the past 12 months? 6/30/2014 <br /> 12. Tank tightness testing completed within the required time frame? L1 Z <br /> 13. Line tightness testing completed within the required time frame? = ❑ <br /> 15. Other required testis maintenance was completed within required time frame? List test/maintenance items below) <br /> Describe Test/Maintenance: TP 201.3&TP201.6 <br /> Describe Test/Maintenance: I Li I ❑ <br /> FACILITY EMPLOYEE TRAINING Yes No UNIA16. Have all facIli em to ees received the re uired on-the-nob trainin within the ast ear? <br /> 17. Have all facili em to ees hired within the 2ast 30 d s received the re uired on-the-nob training.? I Ll 1 ❑ <br /> Note: Explain any"No"answers in the"Comments"section on the following page. Those issues require corrective action from <br /> the UST owner/operator. <br />