My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
853
>
2300 - Underground Storage Tank Program
>
PR0231460
>
BILLING 1985-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 2:50:24 PM
Creation date
11/7/2018 12:29:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1998
RECORD_ID
PR0231460
PE
2381
FACILITY_ID
FA0001369
FACILITY_NAME
7-ELEVEN INC. STORE #21756
STREET_NUMBER
853
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
853 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\853\PR0231460\BILLING 1985-1998.PDF
QuestysFileName
BILLING 1985-1998
QuestysRecordDate
8/10/2017 5:25:54 PM
QuestysRecordID
3568206
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CAUPORNIA c' <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR_SAPWTANK SYSTEM <br /> MARK ONLY ❑ / NEW PERMIT ❑ 3 RENEWAL PERMIT 2!T5 CHANGE OF INFORMATION ❑ TPERMANENTLY ON SITE / <br /> ONE ITEM F72 INTERIM PERMIT F74 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOV <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 7— GO. / <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A OWNERS TANK L D.e B. MANUFACTURED BY: kl <br /> C. DATE INSTALLED(MO/DAY/YEAR) D. TANK CAPACITY IN GALLONS: <br /> IIJANKCONTENTS IFA-11S MARKED.COMPL ITEM C. r <br /> MOTOR VEHICLE FUEL OIL B. C EDUNLEADED 18REGULAR 3 DIESEL ❑ 6 AVIATION GAS <br /> A PREMIUMLLLJJJJ 4 GASAHOL <br /> ❑ 2 PETROLEUM 80 EMPTY 1 PRODUCT �UNLEAOED ❑ 5 JET FUEL ❑ 7 METHANOL <br /> ❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM 0. BELOW) <br /> D. IF(A1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.4: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.S.AND C.AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ A SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> 1 BA <br /> B TANK RE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 8 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary T9N[) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ i RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING <br /> LINING NLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO_ <br /> ❑ I POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> D.CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE KNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U A FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U T STEEL W/COATING A U 8 100% METHANOL COMPATIBLE WfFRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ O MDNRORING ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> 1 AL CHECK 2 INVENTORY RECONCILIATION ED VADOZE MONITORING C:] A AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> u 6 TANK TESTING ❑ 7 INTERSTMALMONTTORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> Vi.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAV/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO ❑ <br /> SUBSTANCE REMAINING GALLONS I INERTMATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME GATE <br /> (PRINr6D L 919NAT9REl <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY a JURISDICTION x FACILITY n TANK#10 _qL14�41 <br /> STATE I.D.# LI-Ei-, /CI 03// <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATEIF <br /> I✓ CY <br /> ^� UC <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> �- <br /> •,r <br />
The URL can be used to link to this page
Your browser does not support the video tag.